Answers are grounded in this paper and cite their sources.
This assessment shows removal torque differences in orthodontic miniscrews, indicating manual methods may enhance stability.
Aim To compare the maximum removal torque (MRT) of orthodontic miniscrews inserted using a manual driver versus a contra-angle motor-driven method. Material and Methods Forty self-drilling, tapered orthodontic mini-implants (8 mm length, 1.65 mm diameter) were inserted into artificial bone blocks without predrilling. Twenty were placed using a manual driver and 20 with a motor-driven contra-angle driver (40 rpm), all at a 90° angle. MRT was measured using a digital torque gauge. Statistical analysis was performed using the paired t -test ( P < .05) in International Business Machines (IBM) Statistical Package for the Social Sciences (SPSS) v24.0. Results The mean MRT was 7.46 N·cm for the manual insertion group and 6.95 N·cm for the contra-angle driver group. The difference of 0.51 N·cm was statistically significant ( P < .0001). MRT values ranged from 6.8 to 8.6 N·cm in the manual group and 6.3-7.6 N·cm in the contra-angle group. Conclusion Manual insertion yielded a higher average MRT than the contra-angle driver, with the difference being statistically significant. This suggests a potential clinical advantage of manual insertion in achieving greater primary stability.
No takes yet. Share an insight, caveat, or question.
Diana Hrant Ter- Poghosyan (2025) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: