Answers are grounded in this paper and cite their sources.
Analysis demonstrates power loss reduction in three-level converters, indicating improved control strategies for stability.
In high-power three-level converters, busbar stray inductance critically influences switching transient and thermal distribution. This paper establishes a parametric stray inductance model for laminated busbars and analyzes its impact on commutation paths. To resolve thermal imbalance, a power loss thermal balance method optimizes control strategies, enabling stable commutation path switching and preventing system instability at switching points. The key is to propose weighting factors based on stray parameters for dynamic energy exchange among internal, external, and clamp switches, combined with case temperature-dependent modulation to achieve thermal balance in three-level converters. The accuracy of the model established and the feasibility of the adopted approach are verified by simulation studies in MATLAB/Simulink and experiments based on a 900 V Alternating Current (AC) power system.
No takes yet. Share an insight, caveat, or question.
Tang et al. (2025) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: