December 5, 2025Applied Sciences3 citationsOpen Access

Analysis of the Fire Behavior of Building-Integrated Photovoltaics (BIPV) as Façade Materials

View Full Paper
KPKye Won ParkEJEun-Goo JeonJJJong Jin Jeong

Key Points

  • Peak heat release rate of 898 kW observed in BIPV modules during tests, drastically higher than benchmarks.
  • Fire performance indicators reveal a cascading failure mechanism unique to Building-Integrated Photovoltaics.
  • Testing included modified standards to assess fire behavior in extreme conditions confronting facade materials.
  • Findings suggest a systemic fire hazard unique to BIPV, indicating weaknesses in current safety assessment protocols.

Abstract

This study provides a comprehensive analysis of the fire hazards associated with Building-Integrated Photovoltaics (BIPV), using Aluminum Composite Panels (ACP) as a benchmark. Large-scale fire tests, modified from ISO 13785-1, were conducted on vertically installed BIPV modules to observe their fire behavior under conditions simulating a severe fire. The experimental process involved measuring key fire performance indicators, leading to the identification of a cascading failure mechanism. The BIPV modules demonstrated a peak Heat Release Rate (HRR) up to hi times higher (max. 898 kW) and smoke production nearly 10 times greater than the ACP baseline. The analysis reveals a distinct, multi-stage failure sequence that defines the systemic fire hazard of BIPV. Initially, a phenomenon strongly indicative of a chimney effect within the rear air cavity accelerates concealed fire spread. This rapid heating induces thermal stress, leading to extensive specimen damage termed cracking. This cracking event acts as a critical turning point, triggering a rapid release of trapped pyrolyzates and driving the fire to its peak intensity. This chain of events constitutes a unique hazard signature not observed in conventional cladding. The findings conclude that the fire risk of BIPV is a systemic issue, challenging the adequacy of component-level testing and highlighting the need for safety standards that assess the façade as a complete assembly.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Park et al. (2025) studied this question.

synapsesocial.com/papers/6932313d8e51979591dcef7chttps://doi.org/10.3390/app152312807
Ask AI
Helpful
Bookmark
Share
View Full Paper

Also Consider

Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context:

  1. 1Large-scale experimental study of thermal performance of building-integrated photovoltaic façade in an enclosure fire2026 · 1 citations
  2. 2Fire Dynamics and Evacuation Simulation Study on the Library Adapting BIPV Based on the Experimental Data of a Cone Calorimeter2024 · 1 citations
  3. 3Fire safety of building integrated photovoltaic systems—State of the art2024 · 5 citations
  4. 4Modelling the structural response of Building Integrated Photovoltaic (BIPV) systems in fire2025 · 1 citations
  5. 5Building stock’s renovation in urban areas by BIPV design: Energy, structural and fire safety considerations2026