April 7, 2026Journal of Building Engineering1 citationsOpen Access

Large-scale experimental study of thermal performance of BIPV façade in an enclosure fire

View Full Paper
CXChengming XiaoRZRui ZhouDRDezhi Ran

Key Points

  • This study aims to investigate the fire performance and thermal behavior of BIPV façades during large-scale fire scenarios.
  • Conducted 16 large-scale fire tests on BIPV façades in a controlled setting.
  • Examined cadmium telluride and monocrystalline silicon BIPV components along with traditional glass.
  • Measured thermal breakage, fallout behavior, and flame dynamics during the fires.
  • BIPV façades exhibited self-sustained burning even after fire extinction.
  • Significant differences in breakage and fallout times between BIPV and traditional glass façades were noted.
  • Double-glazed PV panels with tempered glass showed the best fire performance.

Abstract

Building Integrated Photovoltaic (BIPV) façades play a significant role in enhancing the renewable energy performance and sustainability of modern buildings. However, fire incidents are becoming increasingly common in BIPV systems, yet little is known about the fire performance of BIPV façade in real large-scale fire scenarios. In this work, a total of 16 large-scale fire tests were conducted to investigate the thermal breakage and fallout of BIPV façade in a compartment fire, with a dimension of 1400 × 1400 × 1800 mm 3 . Cadmium telluride and monocrystalline silicon BIPV curtain wall components were selected for this study, with traditional glass included for comparison. Significant differences were observed between PV façade and traditional glass façade, with the former exhibiting self-sustained burning, even after the fire extinction. The types of PV panels significantly impact the breakage and fallout times and behavior, as the new openings caused by PV panel fallout alter the stable ventilation condition and induce more flame ejection, resulting in a significant heat flux compared to control cases without samples. Among the tested configurations, double-glazed PV panels with tempered glass demonstrated the best fire performance and are therefore recommended for BIPV façade design. The experimental results would provide important references for the fire safety design of emerging BIPV high-rise buildings. • The large-scale fire tests of different types of BIPV façades were conducted • Self-sustained burning of interlayers occurred significant, even after the fuel had burnt out • The type of glass panel is a key factor in determining the thermal behavior of PV façade • Interaction between PV panels and compartment fire dynamics was revealed

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Xiao et al. (2026) studied this question.

synapsesocial.com/papers/69d49f1cb33cc4c35a227ac7https://doi.org/10.1016/j.jobe.2026.116033
Ask AI
Helpful
Bookmark
Share
View Full Paper

Also Consider

Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context:

  1. 1A review study about energy renovation of building facades with BIPV in urban environment2018 · 167 citations
  2. 2Cracking behavior of glazings with different thicknesses by radiant exposure2011 · 14 citations
  3. 3Review on recent trend of solar photovoltaic technology2016 · 293 citations
  4. 4Thin film photovoltaics1996 · 104 citations
  5. 5Experimental Studies on the Flammability and Fire Hazards of Photovoltaic Modules2015 · 52 citations