Evaluation shows CERES longwave radiation estimates decline in accuracy during temperature inversions, suggesting algorithm refinement is necessary.
This study assessed the performance of the Clouds and the Earth’s Radiant Energy System (CERES) surface longwave downward radiation (SLDR) products under the atmospheric temperature inversion (ATI) conditions for the first time. Three years of ground-measured SLDRs from 409 globally distributed stations across four flux networks were employed, and the collocated MODIS atmospheric profile product was used to identify the ATI profiles at each flux station. All three SLDR estimate algorithms (Models A, B, and C) show a pronounced accuracy decline under ATI conditions, regardless of region (polar or non-polar) or time of day (daytime or nighttime). Under ATI conditions, the Bias/RMSE increases by approximately 10.0/5.0 W/m2 for Models A and B, 5.0/1.0 W/m2 for Model C. Sensitivity analysis reveals that the concurrent atmospheric moisture inversion (AMI) compounds this degradation; both the Bias and RMSE increase with the AMI intensity. These results underscore the need to refine CERES SLDR algorithms in the future.
No takes yet. Share an insight, caveat, or question.
Sun et al. (2025) studied this question.