Investigation reveals shear strength increases with inclined shear planes in UHPFRC reinforced with steel fibres, suggesting optimal design strategies.
This study investigates the interfaces of ultra-high-performance fibre-reinforced concrete (UHPFRC). The interfaces of UHPFRC-to-UHPFRC were studied using two techniques: (i) slant shear test and (ii) shear key test. Moreover, the glass fibre-reinforced polymer (GFRP) rebars were also used in the shear plane to optimise durability. Six UHPFRC push-off specimens with different GFRP reinforcement ratios and changing shear plane angles were investigated and compared to existing models and codes. The results showed that the slant shear and shear test performed better without adding the epoxy agents due to the presence of steel fibres, which provided the excellent benefit of bridging the cracks and increasing the friction resistance. Furthermore, the shear strength increased substantially with inclined shear planes, rising from 607 kN in the vertical case to 1837 kN at a 60° inclination. However, the existing equations for predicting the shear strength overpredict the shear strength with a vertical shear plane and underpredict the shear strength of the angled shear plane. The test results also confirm that steel fibres enhance shear transfer through crack bridging, while epoxy weakens the interface by limiting mechanical interlock. The linear elastic behaviour of GFRP rebars also influences the shear transfer mechanism by contributing dowel action without yielding.