Internal stability (IS) erosion tests were conducted on broadly graded materials to better understand the effect of the scalped-and-replaced method of removing oversize particles on IS erosion testing. Four gradations (three internally unstable and one internally stable), and their scalped-and-scalped gradations were evaluated under upward flow in three large rigid-wall permeameters (300, 500, and 1000 mm in diameter). The limited test results suggest that scalp-and-replacement of oversize particles coarser than 4 × d30 has no significant effect on IS assessment of the original gradation. The permeameter-to-particle diameter ratio (D/dmax) in the tests varied from 5 to 13. The limited test results suggest D/dmax ≥ 6·5 is acceptable for IS erosion tests in a rigid-wall permeameter if proper measures are taken to minimise preferential erosion along the permeameter wall.
No takes yet. Share an insight, caveat, or question.
Li et al. (2025) studied this question.