An optical levitation system in a vacuum is an efficient system to investigate the dynamics of isolated micro- and nanoparticles. However, the motion and stability of the trapped particles in this system can be affected by the internal temperature, which remains a challenge to measure. Conventional methods are constrained by material specificity or lack the capability for direct temperature measurement. Here, we demonstrate the application of Raman thermometry for non-contact temperature detection of an optically levitated fused silica sphere in vacuum. In addition, the experimental results reveal a linear increase in particle temperature with laser power, consistent with photothermal theory. The integration of Raman thermometry with the optical levitation system enables high-precision thermal sensing at the microscale, offering significant potential for applications in precision metrology and fundamental physics.
No takes yet. Share an insight, caveat, or question.
Li et al. (2025) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: