Answers are grounded in this paper and cite their sources.
Novel four-bore carbon fiber microelectrode platform detects cadmium, dopamine, and serotonin, indicating advancements in neurochemical monitoring.
Simultaneous detection of multiple neurochemicals and toxic metal ions in real time remains a major analytical challenge in neurochemistry and environmental sensing. In this study, we present a novel, biocompatible, laser-trimmed four-bore carbon fiber microelectrode (CFM) platform capable of ultra-fast, multi-analyte detection using fast-scan cyclic voltammetry (FSCV). Each of the four carbon fibers, spaced nanometers apart within a glass housing, was independently functionalized and addressed with a distinct waveform, allowing the selective and concurrent detection of four analytes without electrical crosstalk. To validate the system, we developed two electrochemical detection paradigms: (1) selective electrodeposition of gold nanoparticles (AuNPs) on one fiber for enhanced detection of cadmium (Cd2+), alongside dopamine (DA), arsenic (As3+), and copper (Cu2+); and (2) Nafion-modification of two diagonally opposing fibers for discriminating DA and serotonin (5-HT) from their interferents, ascorbic acid (AA) and 5-hydroxyindoleacetic acid (5-HIAA), respectively. Scanning electron microscopy and energy-dispersive X-ray spectroscopy analysis confirmed surface modifications and the spatial localization of electrodeposited materials. Electrochemical characterization in tris buffer, which mimics artificial cerebrospinal fluid, demonstrated enhanced analytical performance. Compared to single-bore CFMs, the four-bore design yielded a 28% increase in sensitivity for Cd2+ (147.62 to 190.02 nA µM−1), 12% increase for DA (10.785 to 12.767 nA µM−1), and enabled detection of As3+ with a sensitivity of 0.844 nA µM−1, which was not possible with single-bore electrodes within the mixture of analytes. Limits of detection improved twofold for both DA (0.025 µM) and Cd2+ (0.005 µM), while As3+ was detectable down to 0.1 µM. In neurotransmitter-interference studies, sensitivity increased by 39% for DA and 33% for 5-HT with four-bore CFMs compared to single-bore CFMs, despite modest Nafion diffusion onto adjacent fibers. Overall, our four-bore CFM system enables rapid, selective, and multiplexed detection of chemically diverse analytes in a single scan, providing a highly promising platform for real-time neurochemical monitoring, environmental toxicology, and future integration with AI-based in vivo calibration models.
No takes yet. Share an insight, caveat, or question.
Udawaththa et al. (2025) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: