Hysteresis primarily affects the positioning accuracy of the magnetic shape memory alloy-based actuator (M-SMAA). This paper proposes the use of the nonlinear autoregressive moving average with an exogenous input (NARMAX) model to describe the complex dynamic hysteresis of M-SMAA. First, an improved Prandtl–Ishlinskii operator is proposed as the exogenous variable function for the NARMAX model, using a hyperbolic tangent function as the input to the exogenous variable function, to better capture and represent the multivalued mapping hysteresis in M-SMAA. Then, a long short-term memory neural network is introduced to construct the NARMAX model, further optimizing its performance. Finally, the experimental results verify the effectiveness of the model.
No takes yet. Share an insight, caveat, or question.
Wu et al. (2025) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: