This study evaluates the corrosion performance of hybrid aluminium components comprising built and substrate regions. The hybrid system, developed via additive and subtractive methods, was divided to separate individual parts for microstructural and electrochemical analysis in 1 M HCl using Open Circuit Potential (OCP), Electrochemical Impedance Spectroscopy (EIS), Potentiodynamic Polarization (PDP), and Chronoamperometry were used to assess corrosion kinetics, passive film stability, and time-dependent degradation. Scanning Electron Microscopy (SEM) with Energy Dispersive Spectroscopy (EDS) was used to characterize surface morphology before and after corrosion, identifying phase distribution and localized corrosion. The results pinpoint the electrochemical differences between two hybrid configurations - Sample E (Al 7 built on 6082 substrate) and Sample F (Al 10 built on 6082 substrate), with one typical configuration (Sample E) exhibiting superior corrosion resistance across both its built and substrate regions due to a more stable passive layer and refined microstructure.
No takes yet. Share an insight, caveat, or question.
Oguntuyi et al. (2025) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: