Key result
Novel spectrophotometric method accurately quantifies paclitaxel with ~100% recovery.
Why the study?
Paclitaxel is an important anticancer bioactive compound, requiring an accurate and robust analytical method for its quantification.
A novel, direct, and reliable spectrophotometric method using osmium tetroxide was developed and validated for the accurate quantification of paclitaxel in pharmaceutical formulations and biological fluids.
May offer simple paclitaxel assay in formulations; leaves open validation in biological fluids before clinical use.
Paclitaxel (Pac) is an important anticancer bioactive compound, and the availability of an accurate and robust analytical method for its quantification is of utmost importance. In this investigation, a novel, direct, and reliable spectrophotometric method has been proposed for the estimation of Pac via a complex formation reaction with osmium (Os). The method was based on the reaction of Pac with Os tetroxide, which produced a yellowish-brown complex. The resulting complex is soluble in water and displays a maximum absorption peak at 482 nm. The reaction conditions, including reactant concentration, pH, temperature, and reaction time, were optimized to obtain the best spectrophotometric response. A thorough method validation study was conducted, demonstrating that the calibration curve is linear over the concentration range of 1.0–55 μg/mL and follows Beer’s law, with a molar absorptivity of 3.01 × 10⁻4 L/mol⁻1.cm⁻1. The limit of detection (LOD) and limit of quantitation (LOQ) were 0.0098 and 0.0328 μg/mL, respectively. The recovery values were planned and found to be 98.70%–100.23%. At the same time, the precision values (represented by relative standard deviation percent [RSD%]) were better than 0.81% (in injections) and 1.859% (in biological fluids), depending on the Pac concentration. The suggested method was successfully applied to estimate Pac in a pharmaceutical formulation (as injections) and in spiked biological fluids (serum and urine), with results showing good accuracy and precision compared to the reference method.
No takes yet. Share an insight, caveat, or question.
A.A.SALEEM et al. (2025) studied this question. The novel spectrophotometric method for quantifying paclitaxel showed linearity from 1.0–55 μg/mL, with LOD of 0.0098 μg/mL and recovery values between 98.70%–100.23%.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: