Key result
Estimating cardiac index from physiologic monitor data fails to reliably classify individual patients versus thermodilution.
Why the study?
Cardiac index is a key indicator of end-organ perfusion in cardiac surgery patients but is not routinely measured in all cases.
Does estimating cardiac index using routinely available physiologic monitor data accurately reflect invasive thermodilution measurements in adult cardiac surgical patients?
Does estimating cardiac index using routinely available physiologic monitor data accurately reflect invasive thermodilution measurements in adult cardiac surgical patients?
Routinely collected physiologic data can generate population-level cardiac index estimates in adult cardiac surgery patients, but individual-level discrimination of low CI is too limited to replace invasive monitoring.
Supports population-level CI estimates from routine monitors; leaves open replacement of invasive thermodilution for individual cardiac surgery patients.
Cardiac index (CI) is a key physiologic indicator correlated with end-organ perfusion in cardiac surgical patients, yet it is not routinely measured in all cases. This study evaluated the accuracy of estimating CI using routinely available physiologic monitor data, adjusted for relevant patient, physiologic, and procedural factors documented in perioperative anesthesia records. We analyzed anesthesia records from adult cardiac surgical patients with thermodilution-based CI measurements across seven US hospitals from 2014 to 2022. Four published formulas—based on intraoperative blood pressure and heart rate—were used to estimate CI in generalized linear models, with adjustment for perioperative patient and procedure characteristics. Bland-Altman analysis compared adjusted CI estimates to reference thermodilution CI values. The ability of each estimator to classify patients with low CI (< 2.2 L/min/m²) was assessed for concordance. In a cohort of 5,989 patients, the median (IQR = interquartile range) thermodilution-based CIs were 2.1 (1.8–2.6) and 2.4 (2.0–2.9) L/min/m² before and after cardiopulmonary bypass, respectively. The best-performing formula, Liljestrand and Zander, achieved mean absolute errors of 0.45 and 0.47 L/min/m² before and after bypass, respectively. However, its reliability in classifying low CI was limited (Cohen’s kappa = 0.26 pre-bypass, 0.20 post-bypass). Routinely collected physiologic and patient data can be used to generate population-level cardiac index estimates in adult cardiac surgery patients when appropriately adjusted, though individual-level discrimination of low CI is limited. These findings inform future large-scale perioperative hemodynamic research.
No takes yet. Share an insight, caveat, or question.
Balczewski et al. (2025) studied this question. Estimating cardiac index using physiologic monitor data showed mean absolute errors of 0.45 and 0.47 L/min/m² before and after bypass, but low individual-level classification reliability.