Key result
Pacemaker implantation is linked to a 1-point improvement in subjective sleep quality in bradyarrhythmia.
Why the study?
Poor subjective sleep quality is common in patients with bradyarrhythmia and impairs QOL, but pacemaker implantation may have a favorable effect.
Does permanent cardiac pacemaker implantation improve subjective sleep quality and quality of life in patients with symptomatic bradyarrhythmia?
Observational (n=89)
No
Does permanent cardiac pacemaker implantation improve subjective sleep quality and quality of life in patients with symptomatic bradyarrhythmia?
Permanent pacemaker implantation in patients with symptomatic bradyarrhythmia significantly improves subjective sleep quality and mental health-related quality of life.
Answers are grounded in this paper and cite their sources.
Pacemaker implantation was associated with better sleep quality in bradyarrhythmia; extends observational data but leaves open need for randomized confirmation.
BACKGROUND: Patients with bradyarrhythmia requiring pacemaker implantation often report disrupted sleep, which could be related to bradyarrhythmia, apprehension of having heart disease and undiagnosed sleep disorders, resulting in impaired quality of life (QOL). We aimed to assess the prevalence of poor subjective sleep quality in patients with bradyarrhythmia requiring pacemaker implantation and its effect on sleep quality. METHODS AND RESULTS: Patients undergoing permanent pacemaker implantation for bradyarrhythmia were evaluated for subjective sleep quality and health-related QOL using the Pittsburgh Sleep Quality Index (PSQI) and Short Form-8 (SF-8) before and after pacemaker implantation. Poor subjective sleep quality was defined as PSQI score ≥6. Of 89 enrolled patients, 54 (60.7%) reported poor subjective sleep quality. A greater PSQI score indicative of poor sleep quality was likely to be observed in patients who had greater left ventricular ejection fraction and were treated with calcium-channel blockers, as well as in patients with more frequent sleep disturbance-related complaints/symptoms. After pacemaker implantation, the PSQI score improved significantly (from a median score of 6.0 to 5.0; P=0.015) proportional to an improvement in the mental component summary score. CONCLUSIONS: Poor subjective sleep quality is common among patients with bradyarrhythmia, contributing to impaired QOL. Pacemaker implantation may have a favorable effect on subjective sleep quality, and QOL for such patients.
No takes yet. Share an insight, caveat, or question.
Hiki et al. (2025) conducted an observational in Bradyarrhythmia (n=89). Cardiac pacemaker implantation vs. Baseline (before implantation) was evaluated on Subjective sleep quality assessed by the Pittsburgh Sleep Quality Index (PSQI) score (p=0.015). Cardiac pacemaker implantation improved subjective sleep quality in patients with bradyarrhythmia, reducing the median Pittsburgh Sleep Quality Index score from 6.0 at baseline to 5.0.
Synapse has enriched 10 related papers. Consider them for comparative context: