Adaptive multi-objective optimization improves reactive power control in offshore wind farms, suggesting enhanced security and efficiency.
As the proportion of renewable energy generation in the power grid continues to rise, the operational state of the power system changes frequently with fluctuations in renewable power output. However, the traditional fixed-weight multi-objective reactive power optimization method lacks the necessary flexibility and adaptability, as it is unable to dynamically adjust the priority levels of different objectives based on real-time operating conditions (such as load fluctuations and changes in network structure). As a result, its optimization decisions may deviate from the system’s most urgent economic or security needs. To address this issue, this paper proposes an adaptive multi-objective reactive power optimization control method. The proposed approach formulates the objective function as the weighted sum of system active power loss and voltage deviation at the grid connection point, with weight coefficients adaptively adjusted based on the voltage deviation at the grid connection point. First, the relationship between voltage fluctuations at the offshore wind farm grid connection point and active/reactive power output is analyzed, and a corresponding reactive power allocation model is established. Second, taking into account the input–output characteristics of wind turbine generators and static var compensators, a reactive power control model is constructed. Third, considering offshore operational constraints such as power and voltage limits, a weighted variation particle swarm optimization algorithm (WVPSO) is developed to solve for the reactive power control strategy. Finally, the proposed method is validated through tests using a practical offshore wind farm as a case study. The test results demonstrate that, compared with the traditional fixed-weight multi-objective reactive power optimization approach, the proposed method can rapidly adjust the priority of each optimization objective according to the real-time grid conditions, achieving effective coordinated optimization of both active power loss and voltage at the grid connection point, and the voltage deviation is kept within 5%, even with power system fluctuations. In addition, compared with the traditional PSO algorithm, for various test situations, WVPSO exhibits above 15% improvement in solution speed and enhanced solution accuracy.
No takes yet. Share an insight, caveat, or question.
Hu et al. (2026) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: