PulseExploreJournal ClubDebatesTrendingResearchersJournals
Instagram
HomeExploreJournal ClubTrending
Synapse
⌘+K
Synapse
January 17, 2026Energies0 citationsOpen Access

Carbon–Electricity–Heat Coupling Process for Full Unit Carbon Capture: A 1000 MW Case in China

View Full Paper
JCJingchun ChuEnergy Research InstituteYYY. R. YangEnergy Research InstituteLZLiang ZhangChinese Academy of Sciences

Key Points

  • The aim is to optimize carbon capture processes and improve energy efficiency in coal-fired power plants.
  • Establishment of mathematical model equations for the carbon-electricity-heat coupling process
  • Identification of dual-element coupling convergence mechanism
  • Quantitative analysis of operational parameters and system performance metrics
  • Proposal of innovative coupled modes: steam thermal storage and chemical solvent storage
  • Power generation impact rate under full thermal harnessing analysis (THA) is 25.7%, lower than 30% THA conditions at 27.7%
  • Specific power penalty for carbon capture decreases from 420.7 kW·h/tCO2 to 366.7 kW·h/tCO2
  • Each 0.1 GJ/tCO2 increase in thermal consumption results in a 2.83% rise in unit electricity consumption
  • Steam thermal storage effectively reduces peak-period capture energy consumption
  • Chemical solvent storage mode eliminates peak power generation impact, enhancing operational safety

Abstract

Carbon capture is pivotal for achieving carbon neutrality; however, its high energy consumption severely limits the operational flexibility of power plants and remains a key challenge. This study, targeting a full flue gas carbon capture scenario for a 1000 MW coal-fired power plant, identified the dual-element (“steam” and “power generation”) coupling convergence mechanism. Based on this mechanism, a comprehensive set of mathematical model equations for the “carbon–electricity–heat” coupling process is established. This model quantifies the dynamic relationship between key operational parameters (such as unit load, capture rate, and thermal consumption level) and system performance metrics (such as power output and specific power penalty). To address the challenge of flexible operation, this paper further proposes two innovative coupled modes: steam thermal storage and chemical solvent storage. Model-based quantitative analysis indicated the following: (1) The power generation impact rate under full THA conditions (25.7%) is lower than that under 30% THA conditions (27.7%), with the specific power penalty for carbon capture decreasing from 420.7 kW·h/tCO2 to 366.7 kW·h/tCO2. (2) Thermal consumption levels of the capture system are a critical influencing factor; each 0.1 GJ/tCO2 increase in thermal consumption leads to an approximate 2.83% rise in unit electricity consumption. (3) Steam thermal storage mode effectively reduces peak-period capture energy consumption, while the chemical solvent storage mode almost fully eliminates the impact on peak power generation and provides optimal deep peak-shaving capability and operational safety. Furthermore, these modeling results provide a basis for decision-making in plant operations.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Chu et al. (2026) studied this question.

synapsesocial.com/papers/696b26d7d2a12237a934a1d5https://doi.org/10.3390/en19020423
Ask AI
Helpful
Bookmark
Share
View Full Paper