Phantom and in vivo assessments demonstrate improved cardiac MRI mapping with a deep image prior, suggesting enhanced image quality.
Background 0.55T systems offer unique advantages and may support expanded access to cardiac MRI. Purpose To assess the feasibility of 0.55T cardiac MR Fingerprinting (MRF), leveraging a deep image prior reconstruction to mitigate noise. Study Type Phantom and prospective in vivo assessment. Population ISMRM/NIST MRI system phantom and 18 healthy subjects (11 female; ages 28 ± 8 years). Field Strength and Sequences MRF, modified Look‐Locker inversion recovery (MOLLI), and T 2 ‐prepared balanced steady state free precession (T 2 ‐bSSFP) at 0.55T. Assessment MRF T 1 and T 2 maps were reconstructed using (1) a low‐rank technique with sparse and locally low‐rank regularization (SLLR‐MRF) and (2) a deep image prior (DIP‐MRF). Accuracy and precision of MRF and conventional sequences were evaluated in a phantom. In vivo performance of MRF was evaluated in the 18 healthy subjects, with 7 subjects also undergoing conventional mapping. Myocardial T 1 and T 2 values were compared among methods and image quality scored by three readers (2, 3, and 4 years of experience) on a 5‐point scale. Statistical Tests Linear regression, Bland–Altman, intraclass correlation coefficient, and one‐way ANOVA with p < 0.05 considered significant. Results Mean measurements in the left ventricular septum were 671 ± 31 ms (MOLLI), 761 ± 147 ms (SLLR‐MRF), and 686 ± 39 ms (DIP‐MRF) for T 1 , and 63.5 ± 5.7 ms (T 2 ‐bSSFP), 47.5 ± 12.7 ms (SLLR‐MRF), and 45.2 ± 4.5 ms (DIP‐MRF) for T 2 . Compared to conventional mapping, DIP‐MRF exhibited significantly lower T 2 but no differences in T 1 ( p > 0.99). Standard deviations within the myocardium were significantly lower with DIP‐MRF compared to SLLR‐MRF (39 vs. 147 ms for T 1 and 4.5 vs. 12.7 ms for T 2 ). Overall image quality ratings were significantly lower for SLLR‐MRF (T 1 : 2.3, T 2 : 2.9), which were significantly lower compared to conventional mapping methods (T 1 : 3.4, T 2 : 3.9), and DIP‐MRF (T 1 : 3.8, T 2 : 4.1) received higher scores. Data Conclusion This study demonstrated the feasibility of cardiac MRF on a commercial 0.55T system, enabled by a deep image prior reconstruction for denoising. Evidence Level 2. Stage of Technical Efficacy 1.
No takes yet. Share an insight, caveat, or question.
Liu et al. (2026) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: