The study of muscle signal classification has been widely explored for the control of myoelectric prostheses. Traditional approaches rely on manually designed features extracted from time- or frequency-domain representations, which may limit the generalization and adaptability of EMG-based systems. In this work, an autoencoder-based framework is proposed for automatic feature extraction, enabling the learning of compact latent representations directly from raw EMG signals and reducing dependence on handcrafted features. A custom instrumentation system with three surface EMG sensors was developed and placed on selected forearm muscles to acquire signals associated with five hand movements from 20 healthy participants aged 18 to 40 years. The signals were segmented into 200 ms windows with 75% overlap. The proposed method employs a recurrent autoencoder with a symmetric encoder–decoder architecture, trained independently for each sensor to achieve accurate signal reconstruction, with a minimum reconstruction loss of 3.3×10−4V2. The encoder’s latent representations were then used to train a dense neural network for gesture classification. An overall efficiency of 93.84% was achieved, demonstrating that the proposed reconstruction-based approach provides high classification performance and represents a promising solution for future EMG-based assistive and control applications.
Caballero et al. (Thu,) studied this question.