PulseExploreJournal ClubDebatesTrendingResearchersJournals
Instagram
HomeExploreJournal ClubTrending
Synapse
⌘+K
Synapse
February 2, 2026Journal of Radiological Protection1 citationsOpen Access

Revealing the radiation dose impact of topogram, and contrast material monitoring scans in paediatric chest CT scans: comparison to adults and establishment of local DRLs

View Full Paper
BSBenjamin SchröerUniversity of Duisburg-EssenBYBerk YildirimHeidelberg UniversityADAydin DemircioğluEssen University Hospital

Key Points

  • This research aims to investigate the impact of planning scans on radiation dose in paediatric chest CT scans and establish local reference levels.
  • Analyzed 102 paediatric and 4498 adult chest CT scans retrospectively
  • Grouped paediatric scans into 5 age groups for comparison with adults
  • Evaluated dose-length products of topogram, pre-monitoring, and monitoring scans
  • Established local diagnostic reference levels for these scan components
  • Dose from planning scans significantly increases as age decreases, particularly for monitoring scans
  • Topogram proportion increased from 0.3% in adults to 1.6% in infants
  • Pre-monitoring proportion rose from 0.5% in adults to 3.5% in infants
  • Monitoring scans contributed 13%–27% of total dose for children under 10 versus 2.2% for adults

Abstract

Abstract Although the radiation dose impact of planning scans prior to the actual computed tomography (CT) scan has been addressed in previous studies, their systematic assessment across paediatric age groups and their relevance for establishing local diagnostic reference levels (DRLs) have not been thoroughly investigated and are not currently included in guideline recommendations. To investigate the influence of radiation dose from topogram, pre-monitoring, and monitoring scans by age on total radiation exposure and whether their doses need to be considered in DRLs and to establish local DRLs for these scan components. 102 chest CT scans with contrast material monitoring from 101 children (median age 12 years, interquartile range (IQR) 7–16 years) and 4498 chest CT scans from 4476 adults (⩾18 years) between January 2021 and May 2023 were retrospectively analysed. Paediatric scans were grouped into 5 age groups and compared with adult scans. The dose-length product (DLP) of topogram, pre-monitoring, and monitoring scans were evaluated and their effect on total radiation dose was analysed. Local DRLs were established for 5 different age groups. Radiation dose proportions of planning scans to total DLP in chest CT increased with decreasing age group (mainly p < 0.05), with the monitoring scan having the greatest impact. The median topogram proportion increased from 0.3% (⩾18 years) to 1.6% (<1 year), the pre-monitoring proportion from 0.5% (⩾18 years) to 3.5% (<1 year), and the monitoring proportion from 2.2% (⩾18 years) to 26.9% (<1 year). In children under 10 years, monitoring scans in chest CT have a large impact on radiation dose, contributing a median of 13%–27% of the total radiation dose compared to adults (median: 2.2%). Therefore, these planning scans should be monitored and included in radiation dose optimization efforts such as DRLs.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Schröer et al. (2026) studied this question.

synapsesocial.com/papers/6980fc37c1c9540dea80df9bhttps://doi.org/10.1088/1361-6498/ae34be
Ask AI
Helpful
Bookmark
Share
View Full Paper

Also Consider

Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context:

  1. 1Radiation exposure from CT scans in childhood and subsequent risk of leukaemia and brain tumours: a retrospective cohort study2012 · 3,706 citations
  2. 2Radiation dose reduction by adjusting bolus tracking parameters in a 320–detector row scanner2018 · 4 citations
  3. 3Cardiac CT in the Preoperative Diagnostics of Neonates with Congenital Heart Disease: Radiation Dose Optimization by Omitting Test Bolus or Bolus Tracking2019 · 18 citations
  4. 4Assessment of patient dose from CT localizer radiographs2013 · 50 citations
  5. 5Patient grouping for dose surveys and establishment of diagnostic reference levels in paediatric computed tomography2015 · 33 citations