Answers are grounded in this paper and cite their sources.
Numerical CFD study compares heat transfer enhancements from different fin geometries in industrial exchangers, indicating effective design options.
One such numerical CFD study (11-E-09) was performed on the industrial shell-and-tube heat exchanger to compare the thermal-hydraulic performance of three fin geometries (external segmented fins, continuous rectangular wrap fins, and internal twisted-tape inserts): These three fin shapes and variations were investigated. All fin designs improved heat transfer relative to the smooth tube baseline. The Type 1 segmented fins, in fact, resulted in an even enhancement of ≈12% in heat transfer with moderate pressure drop. Type 2 helical fins also offered similar thermal enhancement because they maintained surface contact throughout the fins in order to increase overall conductance. The twisted-tape (Type 3) insert generated the most thermal gains (~19% gain) but had a much higher hydraulic penalty. The design of fin geometry to enhance the performance of exchanger while controlling pumping power is suggested by the study
No takes yet. Share an insight, caveat, or question.
Fatimah Al-Hassany (2025) studied this question.
Synapse has enriched 8 closely related papers on similar clinical questions. Consider them for comparative context: