February 2, 2026Magnetic Resonance in Medicine0 citations

An Open‐Source Software Toolbox for Rapid Radiofrequency Coil Design and Evaluation in MRI

View Full Paper
IGIlias I. GiannakopoulosBZBei ZhangJSJosé E. Cruz Serrallés

Key Points

  • This research aims to develop an efficient, open-source software toolbox for designing and evaluating RF coils used in MRI.
  • Developed a full-wave 3D electromagnetic (EM) solver using wire-surface-volume integral equation (WSVIE) method.
  • Implemented a reduced-order model for patient-specific coil simulations.
  • Created a circuit co-simulator for coil tuning and matching.
  • Generated numerical EM basis for performance metrics.
  • Achieved a simulation speed that was 70 times faster than a commercial solver for a 31-channel 7 T head coil.
  • Reduced coil tuning, matching, and decoupling time to 30 minutes from a few days with commercial tools.
  • Maintained an average difference of less than 15% in signal-to-noise ratio maps.

Abstract

ABSTRACT Purpose Image quality and resolution in MRI are fundamentally constrained by the performance of radiofrequency (RF) coils used to excite the spins and receive the signal. Electromagnetic (EM) simulations are essential for optimizing coil performance. Existing tools are often slow, memory‐intensive, and require expensive licenses. To address these limitations, we introduce a novel, comprehensive, open‐source EM simulation tool for RF coil design in MRI. Theory and Methods Our toolbox consists of four complementary software components: (1) a full‐wave 3D EM solver based on the wire‐surface‐volume integral equation (WSVIE), where tensor decompositions reduce memory usage and accelerate simulations for fine body model resolutions; (2) a reduced‐order model technique enabling patient‐specific coil simulations in minutes; (3) a fully automatic circuit co‐simulator for coil tuning, matching, decoupling, preamplifier decoupling, and detuning; and (4) a numerical EM basis generator that can be used to compute ultimate performance metrics. We demonstrated the toolbox with a series of simulations for different applications at 7 T MRI. Results Our proposed reduced‐order model WSVIE solver was 70 times faster compared to a commercial solver for the simulation of a 31‐channel 7 T head coil. Our co‐simulator tuned, matched, and decoupled the array in 30 min, compared to a few days time of manual interactions needed with the commercial package. The average difference between the signal‐to‐noise ratio maps was less than 15%. Conclusion The proposed open‐source simulation framework enables fast, memory‐friendly, accurate, and anatomy‐specific RF coil array design, making it a powerful tool for RF coil engineering.