Key result
Wearable HRV features improve VO2max prediction R² to 0.47 compared to baseline models.
Why the study?
Wearable sensors offer a scalable alternative to cardiopulmonary exercise testing, but whether wearable ECG-derived heart rate variability features improve remote VO2 max estimation in preoperative patients remained unclear.
Does the inclusion of HRV features improve remote VO2 max estimation in a preoperative cohort, and do open-source SQIs accurately assess synthetic ECG signal quality compared to expert clinical assessment?
Observational (n=163)
No
Does the inclusion of HRV features improve remote VO2 max estimation in a preoperative cohort, and do open-source SQIs accurately assess synthetic ECG signal quality compared to expert clinical assessment?
Long-term HRV features can modestly improve remote VO2 max predictions in clinical cohorts, but current open-source ECG signal quality indices show limited reliability and consistency compared to expert clinical assessment.
Answers are grounded in this paper and cite their sources.
May modestly improve preoperative VO2max estimates with wearables; extends sensor research but leaves clinical adoption open.
Background Wearable sensors offer a scalable alternative to cardiopulmonary exercise testing for assessing cardiorespiratory fitness, and there is growing evidence to support their use for remote VO 2 max estimation. This study investigated whether heart rate variability (HRV) measures derived from wearable ECG sensors improve VO 2 max estimations in a preoperative cohort and compared the relative contributions of short- and long-term HRV features. ECG and accelerometer data from 198 participants scheduled for major abdominal surgery (REMOTES study, ClinicalTrials.gov: ID NCT06042023) were collected over 72 h. Measures including physical activity, steps, heart rate, and HRV were extracted. Short-term (5-minutes) and long-term (24-hour) heart rate variability features were extracted from free-living ECG data. Two LASSO regression models with five-fold cross-validation were developed: a baseline model (excluding HRV) and a HRV model. Results After exclusions, 163 participants were included in analyses. The HRV model outperformed the baseline across all metrics, achieving a higher R 2 (0.47 ± 0.12 vs. 0.42 ± 0.13) and lower mean absolute error (2.63 ± 0.34 vs. 2.77 ± 0.38 ml/kg/min), root mean square error (3.38 ± 0.53 vs. 3.54 ± 0.57 ml/kg/min) and absolute percentage error (15.55 ± 2.19% vs. 16.22 ± 2.45%). Analysis of feature contributions identified long-term HRV (SDANN HR 24), age, gender, and step-counts as key contributors to model performance. Conclusion HRV features from wearable data, especially long-term measures, can improve remote VO 2 max predictions in a clinical cohort. While performance gains were small, these findings support the integration of HRV features into remote monitoring systems in real-world settings. Long-term HRV measures derived from heart rate signals offer a practical option for cardiorespiratory fitness assessment, requiring minimal additional processing. Trail registration This study was registered at ClinicalTrials.gov (Clinical trial number: NCT06042023) and was registered retrospectively on 11/09/2023.
No takes yet. Share an insight, caveat, or question.
Syversen et al. (2026) conducted an observational in Cardiorespiratory fitness assessment in preoperative cohort (n=163). Wearable ECG sensor vs. Standard baseline model excluding HRV features was evaluated on VO2max prediction accuracy (R² 0.05, 95% CI 0.00-0.11, p=0.042). Including heart rate variability features from wearable sensors improved VO2max prediction R² by 0.05, achieving a maximum R² of 0.47 compared to 0.42 for the baseline model.
Synapse has enriched 10 related papers. Consider them for comparative context: