Key result
Balloon pressure monitoring yielded a 24-hour radial artery occlusion rate of 2.1% versus 1.5% with traditional volume-guided methods (OR 1.333; 95% CI 0.302-5.879; p>0.05).
Why the study?
Does balloon pressure monitoring reduce 24-hour RAO incidence and improve operational efficiency compared to volume-guided hemostasis in patients undergoing transradial coronary angiography?
RCT (n=390)
randomized
No
Does balloon pressure monitoring reduce 24-hour RAO incidence and improve operational efficiency compared to volume-guided hemostasis in patients undergoing transradial coronary angiography?
Answers are grounded in this paper and cite their sources.
Balloon pressure monitoring for radial artery hemostasis achieves comparable RAO prevention to traditional methods while significantly reducing hemostasis time and personnel requirements.
Background Radial artery occlusion (RAO), occurring in up to 33% of cases, restricts reaccess following transradial angiography. Traditional hemostasis methods, reliant on manual volume adjustments (e.g., initial 18 mL inflation), suffer from inconsistent pressure control and operator dependency. This interim analysis of a large randomized controlled trial (RCT; planned N = 818, interim n = 390) evaluates the efficacy and efficiency of balloon pressure monitoring (±2 mmHg precision), which standardizes compression via real-time manometry, compared to conventional volume-guided approaches. Purpose The study aimed to: (1) compare 24-hour RAO rates between balloon pressure monitoring and traditional methods; (2) assess operational efficiency (time and personnel requirements); and (3) identify predictors of bleeding and RAO. Methods A single-center RCT enrolled 390 patients (of a planned 818) undergoing transradial coronary angiography. Participants were randomized into two groups: the balloon group received phased decompression (initial 260 mmHg, adjusted based on bleeding), while the control group underwent volume-guided hemostasis. Primary outcomes included 24-hour RAO incidence (ultrasound-confirmed), and secondary outcomes encompassed bleeding complications, hemostasis time, and personnel utilization. Statistical analyses adhered to intention-to-treat principles, employing chi-square tests, Mann-Whitney U tests, and multivariate logistic regression. Results Baseline demographics were balanced between groups (all p > 0.05). RAO incidence was 2.1% (4/195) in the balloon group versus 1.5% (3/195) in controls (OR = 1.333, 95% CI: 0.302–5.879; p >0.05). Balloon monitoring significantly reduced median hemostasis time (98 vs. 180 seconds ; p < 0.001) and operator requirements (1 vs. 2 personnel). Multivariate analysis revealed shorter compression time (OR = 0.962, p < 0.001) and diabetes (OR = 2.1, p = 0.032) as independent predictors of bleeding, while no predictors for RAO emerged. Pressure data indicated a median of 170 mmHg (range: 120–260) in non-occluded cases. Conclusions Interim findings demonstrate that balloon pressure monitoring achieves RAO prevention comparable to traditional methods, while significantly improving efficiency. Individualized pressure titration may optimize hemostasis-patency balance. Shorter compression time reduced bleeding risk, and diabetes doubled bleeding odds, highlighting the need for tailored protocols. Final data from 818 participants will validate long-term efficacy and refine pressure guidance strategies. These results support scalable adoption in resource-limited settings.
No takes yet. Share an insight, caveat, or question.
Zhang et al. (2025) conducted an RCT in transradial coronary angiography (n=390). Balloon pressure monitoring vs. volume-guided hemostasis was evaluated on 24-hour RAO incidence (ultrasound-confirmed) (OR 1.333, 95% CI 0.302-5.879, p=>0.05). Balloon pressure monitoring yielded a 24-hour radial artery occlusion rate of 2.1% versus 1.5% with traditional volume-guided methods (OR 1.333; 95% CI 0.302-5.879; p>0.05).