Why the study?
There is limited economic evidence on pulsed field ablation in the UK, especially based on published randomized controlled trial data, to understand its added economic value against established therapies.
Is a dual-energy, lattice-tip pulsed field and radiofrequency ablation catheter cost-effective compared to a conventional radiofrequency ablation catheter in patients with persistent atrial fibrillation?
Is a dual-energy, lattice-tip pulsed field and radiofrequency ablation catheter cost-effective compared to a conventional radiofrequency ablation catheter in patients with persistent atrial fibrillation?
A dual-energy, lattice-tip pulsed field and radiofrequency ablation catheter is estimated to be cost-saving and yield higher QALYs compared to conventional radiofrequency ablation for persistent AF in the English NHS.
Answers are grounded in this paper and cite their sources.
Supports adoption of dual-energy PF/RF catheter in persistent AF; extends RCT evidence with favorable NHS cost-effectiveness.
Background Pulsed field ablation (PFA) is a new form of energy modality for atrial fibrillation (AF) treatment. There are several PFA catheters that are already in use in the United Kingdom (UK). To understand their added economic value, it is important to evaluate them against established therapies. To date, there is limited economic evidence on PFA in the UK, especially based on published randomised controlled trial (RCT) data. Purpose To evaluate the cost-effectiveness of a novel dual-energy, wide-footprint, lattice-tip pulsed field and radiofrequency mapping and ablation catheter (PF/RF) compared to a conventional contact-force sensing radiofrequency ablation catheter (RF), in patients with persistent AF (PersAF), from the perspective of the English National Health Service (NHS). Methods Individual patient-level data from the SPHERE Per-AF RCT were utilised to estimate efficacy, resource utilisation, and health-related quality of life parameters in symptomatic PersAF patients who were refractory or intolerant to at least one class I or class III anti-arrhythmic drug. When trial data did not provide certain parameters, inputs were sourced from published literature. The cost-effectiveness model (CEM) consisted of a hybrid decision tree (one-year time horizon) and a Markov model with three-month cycle length (lifetime time horizon, 40 years) and was developed from the perspective of the English NHS. Unit costs were derived from the National Institute for Health and Care Excellence (NICE) Clinical Guideline for AF Diagnosis & Management (NG196) and NHS national cost collection data. The cost of the ablation procedure was determined using the unit price for a day case from the 2024/25 NHS Tariff. Health benefits were expressed in quality-adjusted life years (QALYs), and all benefits and costs were discounted at 3.5% per year in line with NICE requirements. The results include an initial 90-day blanking period for all studies. Results PF/RF ablation is estimated to be less costly than RF ablation while yielding higher QALYs over a patient’s lifetime. This results in a dominant, cost-saving incremental cost-effectiveness ratio (ICER) with a willingness- to-pay threshold of £20,000 per QALY gained. Over a lifetime horizon, the average total cost per patient was £12,652 for PF/RF and £15,904 for RF. The average QALYs per patient were 10.74 for PF/RF and 10.65 for RF. Statistical analyses demonstrated a reduction in AF recurrence and a lower rate of repeat ablations following initial treatment in the PF/RF intervention arm. The CEM predicted a relative reduction of 13% in time spent in AF recurrence and 0.58 fewer repeat ablations per person for the PF/RF intervention arm. Lower AF recurrence and fewer repeat ablations in the PF/RF arm were the main drivers of the cost-saving results. Conclusion The dual-energy, lattice-tip catheter for treating PersAF patients is cost-saving compared to RF within the English NHS setting.
No takes yet. Share an insight, caveat, or question.
Mellor et al. (2025) studied Persistent atrial fibrillation (PersAF). Dual-energy, lattice-tip pulsed field and radiofrequency mapping and ablation catheter (PF/RF) vs. Conventional contact-force sensing radiofrequency ablation catheter (RF) was evaluated on Cost-effectiveness (Incremental cost-effectiveness ratio and QALYs). Dual-energy PF/RF ablation was cost-saving compared to RF ablation over a lifetime horizon, driven by lower AF recurrence and fewer repeat ablations.