Key result
Fine-tuned RoBERTa classifies angiography reports with 89% accuracy, matching experts and outperforming few-shot prompting.
Why the study?
Free-text invasive coronary angiography reports in EHRs limit research and machine learning applications, while manual annotation is time-consuming and subjective.
Do LLM-based methods (few-shot prompting or fine-tuning) accurately classify unstructured invasive coronary angiography reports compared to manual annotation?
Do LLM-based methods (few-shot prompting or fine-tuning) accurately classify unstructured invasive coronary angiography reports compared to manual annotation?
Both fine-tuned and few-shot LLM approaches achieved near expert-level accuracy in classifying unstructured coronary angiography reports, enabling rapid automated data extraction for clinical research.
Answers are grounded in this paper and cite their sources.
May enable scalable extraction of angiography data for research; leaves open prospective validation before clinical use.
Abstract introduction Large volumes of invasive coronary angiography (ICA) reports are stored in electronic health records (EHRs) worldwide, but their free-text format limits research and machine learning applications. (1) Manual annotation remains the primary structuring method, a time-consuming and subjective process. (2) Recent advancements in natural language processing, particularly large language models (LLMs), offer a promising solution. LLMs excel in processing human language, making them valuable for automated medical data annotation. (3) Purpose Two LLM-based methods were developed and evaluated for the automated classification of ICA reports, facilitating efficient structuring of unstructured clinical data. Methods ICA reports, written in Dutch, from patients with acute coronary syndrome were retrospectively collected from a local EHR system (2010-2022). A random subset of 1000 reports was manually annotated for occlusion, bypass graft presence, macrovascular coronary artery disease (CAD) (binary), intervention type (PCI, CABG or no intervention), and culprit vessel(s) (main and branch). Annotations were based on the cardiologists’ final reports and were reviewed by two researchers, with discrepancies resolved through discussion. The data was randomly split in a training (n=700) and a testing (n=300) set. Two classification approaches were developed: (1) a few-shot prompt engineering (FS) method, using iteratively optimized prompts with a commercially available LLM and (2) a fine-tuning method (FT), trained on multiple state-of-the-art pretrained LLMs. Culprit vessel classification was correct only if predefined labels were exactly matched; partial matches were classified as incorrect. Model performance was assessed using accuracy, macro-averaged F1-scores, and recall. Statistical significance differences between models, were evaluated per label using bootstrap resampling and a paired t-test. Results All ICA reports belonged to unique patients. The Inter-observer agreement for manual annotation ranged from 81% (culprit branch) to 98% (graft label). The best fine-tuning results were obtained with RoBERTa, pretrained on multilingual datasets. (4) Average accuracy was 89% for the FT method and 88% for the FS method. Accuracy of culprit branch prediction and recall of the no CAD prediction were statistically significantly different between the models (FT outperformed FS in culprit branch, FS outperformed FT for no CAD). Most classification errors occurred in selecting the correct culprit branch(es). Conclusion Both methods approached expert-level accuracy, enabling rapid and standardized classification of ICA reports, significantly reducing the time required for dataset creation in large-scale clinical research. Interestingly, the FT method reached similar or better results compared to the much larger FS model. Meaning that with a relatively small annotated dataset, similar results can be achieved in a much less costly manner.
No takes yet. Share an insight, caveat, or question.
Loo et al. (2025) studied Acute coronary syndrome (n=1,000). Fine-tuning (FT) LLM method vs. Few-shot prompt engineering (FS) method was evaluated on Average classification accuracy. A fine-tuned LLM method achieved 89% average accuracy in classifying coronary angiography reports, compared to 88% for a few-shot prompt engineering method, approaching expert-level accuracy.