Neutronic and thermal-hydraulic performance are analyzed for thorium-based fuel in SMR systems, suggesting improved utilization and safety.
A coupled neutronic and thermal-hydraulic assessment is performed for a dual-cooled annular fuel concept applied to light-water SMR conditions. A mixed thorium-based oxide, (Th-233U-235U)O2, is evaluated against conventional UO2 and solid-pin benchmarks while sweeping the inner moderator radius (0.05-0.43165 cm) at constant fuel volume. The thorium annular cases sustain an infinite multiplication factor (kinf) of 1.002-1.003 at EOC and achieve 3-batch discharge burnups of 166.3-173.5 GWd/t, compared with 142.4 GWd/t for solid UO2. Radial peaking remains low (maximum PPF ≈ 1.056, well below the 1.65 Westinghouse-types PWR design limit). All configurations exhibit negative FTC and MTC, with stronger negative feedback at larger inner radii. Thermal-hydraulic results show smooth coolant heating and robust DNBR margins (minimum ∼ 2.3) with negligible sensitivity to inner radius. These outcomes support the feasibility of thorium-based annular fuel for SMR deployment with improved fuel utilization and preserved safety margins.
No takes yet. Share an insight, caveat, or question.
Rifai et al. (2026) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: