Key result
Microaxial flow pump cuts 180-day mortality ~66% vs. standard care in severe AMI-CS.
Why the study?
Does a microaxial flow pump added to standard care reduce 180-day all-cause mortality in adults with STEMI and cardiogenic shock, and is this effect modified by baseline systolic blood pressure?
RCT (n=355)
Open-label
Yes
Does a microaxial flow pump added to standard care reduce 180-day all-cause mortality in adults with STEMI and cardiogenic shock, and is this effect modified by baseline systolic blood pressure?
Odds Ratio: 0.34 (95% CI 0.18–0.63)
p-value: p=<0.001
The survival benefit of microaxial flow pumps in infarct-related cardiogenic shock appears to be driven by patients presenting with profound hypotension (systolic blood pressure < 83 mmHg).
Background Cardiogenic shock remains a severe complication of acute myocardial infarction (AMI-CS), with short-term mortality of 40–50%. Hypotension is a central diagnostic criterion as well as treatment target. The Danish-German (DanGer) Shock trial demonstrated a significant survival benefit from routine use of microaxial flow pump (mAFP) in selected AMI-CS patients. The DanGer Shock trial, along a recently published meta-analysis compiling data from nine individual trials in the field, showed a potential interaction with blood pressure at randomization, warranting further investigation. Purpose Investigate the influence of randomization systolic blood pressure on the treatment effect of mAFP in AMI-CS. Methods Post-hoc analysis of the DanGer Shock trial, which is an international multicenter, open-label clinical trial, randomizing AMI-CS patients to mAFP plus standard care or standard care alone. Inclusion criteria comprised adults with STEMI and cardiogenic shock (systolic blood pressure below 100mmHg or need for vasopressors, lactate > 2.5mmol/L, and left ventricular ejection fraction (LVEF) <45%). Main exclusion criteria were resuscitated out-of-hospital cardiac arrest with persistent Glasgow coma scale <8, mechanical complications, and right ventricular failure. Study endpoints are 180-day all-cause mortality. Statistical methods include cubic spline modeling, Kaplan Meier analysis, log-rank test, and multivariable logistic regression. Results Of the 355 DanGer Shock patients, 351 (98.9%) had available systolic blood pressure at randomization. 4 patients (1.1%) were included based on vasopressor need. The median age was 69 years (IQR:59-76), 74 (21%) females, the median left ventricular ejection fraction (LVEF) was 25% (IQR:15-30), and the median systolic blood pressure at randomization was 82mmHg (IQR:72-91). Patients with an initial systolic blood pressure below the median 82mmHg showed a significant 180-day all-cause mortality reduction when treated with mAFP compared to standard care (OR=0.34 (95%CI: 0.18-0.63), p<0.001). This survival benefit was not evident for systolic blood pressures above the median (OR:=0.96 95%CI: 0.53-1.7), p=0.90), (p for interaction=0.017). When assessing systolic blood pressure as a continuous variable, the same outcome was observed: As seen in Figure 1, patients with a systolic blood pressure below 83mmHg experienced a significant mortality risk reduction when treated with mAFP compared to standard care (p for interaction = 0.021 ). Survival in quartiles of randomization blood pressure is shown in Figure 2. Conclusion This exploratory post-hoc analysis suggests an impact of initial hemodynamic status on the survival benefit of mAFP in AMI-CS. In patients presenting an initial systolic blood pressure below 83 mmHg, treatment with a mAFP was associated with a significantly reduced risk of death. This survival benefit was not evident in patients with initial systolic blood pressures above 83 mmHg.
No takes yet. Share an insight, caveat, or question.
Mikkelsen et al. (2025) conducted an RCT in Acute myocardial infarction with cardiogenic shock (AMI-CS) (n=355). Microaxial flow pump (mAFP) vs. Standard care was evaluated on 180-day all-cause mortality in patients with initial systolic blood pressure below 82mmHg (OR 0.34, 95% CI 0.18-0.63, p=<0.001). In patients with AMI-CS and initial systolic blood pressure <83 mmHg, microaxial flow pump treatment significantly reduced 180-day all-cause mortality compared to standard care (OR 0.34; 95% CI 0.18-0.63; p<0.001).