Analysis integrates computational fluid dynamics and autopsy to evaluate contaminant behavior in ultrapure water systems, indicating material impact on contamination levels.
Ultrapure water (UPW) distribution loops must deliver stable hydraulics while limiting contamination from polymer piping. This study integrates computational fluid dynamics (CFD) with systematic pipe autopsy to examine contaminant behavior in a pilot-scale UPW loop constructed using chlorinated polyvinyl chloride (CPVC) and polyvinylidene fluoride (PVDF) and operated under identical conditions. CFD predicted nearly identical loop-scale velocity, pressure, and temperature fields for both materials, and identified low-shear recirculation at elbows and downstream tees as zones of elevated particle residence. Lagrangian particle tracking (0.05 μm, no-sticking) showed rapid breakthrough and complete flushing within 13 min, providing a hydraulic susceptibility map for transient retention. After eight months of operation, 17 sections were inspected endoscopically and leached at 60 °C. CPVC exhibited yellow–brown discoloration and highly heterogeneous total organic carbon (TOC) release with hot spots of 16–18 mg·L−1, whereas PVDF showed low, spatially uniform TOC (0.4–2.3 mg·L−1) and minimal fouling; inorganic ions remained at sub-mg·L−1 levels for both materials. Overall, geometry governs where contamination can accumulate, while material properties control its magnitude and persistence, with PVDF providing greater resistance to long-term organic contamination than CPVC.