Key result
Totally endoscopic AVR achieves ~0% pooled perioperative mortality and minimal stroke risk.
Why the study?
While isolated AVR is well established through conventional and minimally invasive access, large-scale evidence for the totally endoscopic approach remains limited.
Does totally endoscopic aortic valve replacement (TE-AVR) provide safe and feasible perioperative outcomes in patients requiring aortic valve replacement?
Meta-Analysis (n=1,135)
Does totally endoscopic aortic valve replacement (TE-AVR) provide safe and feasible perioperative outcomes in patients requiring aortic valve replacement?
Answers are grounded in this paper and cite their sources.
No takes yet. Share an insight, caveat, or question.
Totally endoscopic aortic valve replacement demonstrates excellent perioperative safety with near-zero mortality and very low rates of stroke and conversion to sternotomy.
Background and Objectives: Totally endoscopic aortic valve replacement (TE-AVR) is a minimally invasive technique offering potential benefits of reduced surgical trauma and faster recovery compared with median sternotomy or other minimally invasive access. While isolated aortic valve replacement (AVR) is well established through conventional and minimally invasive access, large-scale evidence for the totally endoscopic approach remains limited. This meta-analysis aimed to systematically assess the safety and feasibility of TE-AVR by aggregating perioperative outcomes, including mortality, stroke, conversion, bleeding, paravalvular leak (PVL), and atrial fibrillation (AF). Materials and Methods: A systematic search of PubMed, Embase, and the Cochrane Library was performed, following PRISMA 2020 guidelines. Observational studies and randomized controlled trials reporting outcomes of totally endoscopic or thoracoscopic AVR were eligible. After independent screening and selection, data were analyzed using a single-arm proportion model. Leave-one-out sensitivity analyses were performed to evaluate the influence of individual studies. The protocol was registered in PROSPERO (CRD42024610128). Results: A total of 11 studies comprising 1135 patients were included. The pooled perioperative mortality was 0.00% (95% CI 0.00–0.23; I2 = 0.0%), indicating highly consistent results across cohorts. The stroke incidence was 0.69% (95% CI 0.00–2.07; I2 = 42.7%), confirming the low cerebrovascular risk of this approach. Conversion to sternotomy occurred in 0.00% of cases (95% CI 0.00–0.17; I2 = 0.0%), with no statistical heterogeneity observed. Reintervention for bleeding occurred in 1.75% (95% CI 0.34–3.85; I2 = 43.4%), while PVL was reported in 1.24% (95% CI 0.00–4.22; I2 = 64.0%). AF incidence was 10.54% (95% CI 3.79–19.70; I2 = 90.5%), with substantial between-study heterogeneity, likely related to non-standardized definitions of new-onset AF and variability in postoperative rhythm monitoring and reporting across studies. Conclusions: TE-AVR is a safe and feasible technique associated with very low perioperative mortality, bleeding, and stroke rates, as well as low PVL incidence. The absent conversion rate in our pooled analysis highlights the technical reliability of the procedure. Variability in AF reporting underscores the need for future randomized studies with harmonized definitions. Overall, TE-AVR offers a promising minimally invasive alternative for aortic valve replacement, with potential advantages in recovery (pooled ICU stay 1.86 days), hospital stay (pooled 7.98 days), and aesthetic outcomes.
Anghel et al. (2026) conducted a meta-analysis in Aortic valve disease requiring replacement (n=1,135). Totally endoscopic aortic valve replacement (TE-AVR) was evaluated on Perioperative mortality (Pooled rate, 95% CI 0.00-0.23). Totally endoscopic aortic valve replacement demonstrated a pooled perioperative mortality of 0.00% (95% CI 0.00-0.23) and a stroke incidence of 0.69% (95% CI 0.00-2.07).
Synapse has enriched 10 related papers. Consider them for comparative context: