Answers are grounded in this paper and cite their sources.
Experimental evaluation of pulsating heat pipes in air conditioning systems, suggesting an optimal fill ratio for heat recovery.
Pulsating heat pipes (PHPs) represent a contemporary and highly efficient thermal technology that utilizes the oscillatory motion of a fluid within capillary tubes to facilitate heat transfer from the evaporator (heat source) to the condenser (heat sink), negating the necessity for moving mechanical components. In this work, a comprehensive experimental study of the thermal performance of a PHP heat exchanger (PHPHE) is conducted, designed to recover waste energy in air conditioning systems and exchange heat between two air streams in a counterflow configuration. The system consists of six rows of pulsating heat pipes (PHPs), each containing six turns, divided into three main sections: evaporator, adiabatic section, and condenser, with lengths of 25, 10, and 25 cm, respectively. The novelty of this study lies in applying a multiple pulsating heat pipe heat exchanger (PHPHE) with pure water, methanol, and acetone as the working fluid for air-conditioning systems, which were utilized at three different fill ratios of 50%, 60%, and 70%. The study examines how using it as a working fluid in PHPHE affects HVAC system performance. Tests were carried out using three air flow velocities (0.5, 0.7, and 0.9 m/s) and three evaporator air inlet temperatures (40 °C, 45 °C, and 50 °C) to investigate their effect on the performance of the PHPHE. Results indicated that raising the inlet air temperature to the evaporator has a positive impact on the heat transfer rate. Results indicated that raising the inlet air temperature to the evaporator has a positive impact on the heat transfer rate. At a filling ratio of 50%, the thermal performance of the pulsating heat pipe was consistently superior, attaining the best balance between fluid flow and volume compared to 60% and 70%. The enhancement ranged between 5.2% and 28.6% for acetone, 5.1% to 26.3% for methanol, and 4.1% to 30.3% for water, confirming that a 50% filling ratio provides the most effective operation. Furthermore, acetone demonstrates superior effectiveness compared to methanol and water, achieving 32% effectiveness at a 50% fill ratio under suitable operating conditions. The overall system effectiveness for the three liquids ranged from a minimum of 15% for water to a maximum of 32% for acetone.
No takes yet. Share an insight, caveat, or question.
Moayad et al. (2026) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: