Key result
Modified Mask R-CNN cuts false positives ~31% vs RPN-only model on CTPA for PE while maintaining sensitivity.
Why the study?
High false-positive rates remain a significant challenge in the automated detection of pulmonary embolism using CTPA.
Does a Modified Mask R-CNN with a False-Positive Reduction module improve diagnostic specificity and reduce false positives compared to an RPN-only model in detecting pulmonary embolism on CTPA scans?
Does a Modified Mask R-CNN with a False-Positive Reduction module improve diagnostic specificity and reduce false positives compared to an RPN-only model in detecting pulmonary embolism on CTPA scans?
Integrating a False-Positive Reduction module into a Region Proposal Network significantly reduces false positives and improves positive predictive value in automated pulmonary embolism detection on CTPA.
May reduce false positives in AI-based PE detection on CTPA; hypothesis-generating and requires prospective validation before clinical use.
Background: High false-positive rates remain a significant challenge in the automated detection of pulmonary embolism (PE) using Computed Tomography Pulmonary Angiography (CTPA). This study evaluated the additional value of a False-Positive Reduction (FPR) module integrated into a Region Proposal Network (RPN). Methods: A retrospective analysis of 303 CTPA scans (163 PE-positive and 140 PE-negative) was conducted from a single tertiary institution. Both models were additionally validated on an independent external cohort of 100 CTPA scans (50 PE-positive and 50 PE-negative) from the RSNA PE Challenge dataset. The diagnostic performance of the one-stage RPN-only model was compared with that of a two-stage Modified Mask R-CNN (Region-based Convolutional Neural Network) incorporating the FPR module. Results: The Modified Mask R-CNN exhibited significant improvement in terms of specificity. The false-positive rate per scan decreased by 31% in comparison to the RPN-only model. Although there was a slight reduction in patient-level sensitivity, the Positive Predictive Value significantly increased by 10.5%. Additionally, patient-level specificity for emboli with a volume ≥ 1000 mm3 increased, reflecting a 7.4% relative improvement in detecting clinically significant emboli. Conclusions: The Modified Mask R-CNN significantly reduced false positives while maintaining high sensitivity over a region proposal network.
No takes yet. Share an insight, caveat, or question.
Lee et al. (2026) studied Adults (mean age 63.2 years) undergoing computed tomography pulmonary angiography suspected of or diagnosed with pulmonary embolism (n=303). Two-stage Modified Mask R-CNN with False-Positive Reduction (FPR) module vs. One-stage Region Proposal Network (RPN) only model was evaluated on Patient-level diagnostic performance of pulmonary embolism detection including sensitivity, specificity, positive predictive value (PPV), and false positive rate per scan (Patient-level sensitivity difference −0.028 (p=0.5); Patient-level PPV improvement from 0.65 to 0.718 (10.5% relative increase, p<0.001); False positives per scan reduced from 0.331 to 0.228 (31% reduction, p<0.001); Patient-level specificity increased from 0.8 to 0.859 (7.4% increase, p<0.001), 95% CI Sensitivity 95% CI: Modified Mask R-CNN (0.821–0.950), RPN-only (0.851–0.966), p=Sensitivity p=0.5; PPV p<0.001; False positives per scan p<0.001; Specificity p<0.001). Two-stage Modified Mask R-CNN reduced false positives per scan by 31% and increased patient-level positive predictive value by 10.5% compared to RPN-only model while maintaining high sensitivity (0.892 vs 0.92) in adults undergoing CTPA for pulmonary embolism.