Answers are grounded in this paper and cite their sources.
Prospective evaluation tests the effectiveness of low-dose coronary CT angiography using advanced imaging algorithms, indicating significant reductions in radiation exposure.
Objectives To test the feasibility of 60 kVp double-low-dose coronary CT angiography (CCTA) with a deep learning reconstruction (DLR) algorithm. Materials and methods Eighty-nine patients (44 females, 59.9 ± 13.2 years, 23.1 ± 3.3 kg/m 2 ) with known or suspected coronary artery disease were prospectively enrolled. Each patient underwent the double-low-dose CCTA (60-kVp, 28 mL contrast at 2.5 mL/s) and was immediately followed by routine-dose CCTA (100-kVp, 44 mL contrast at 4.0 mL/s). Routine-dose data were reconstructed using hybrid iterative reconstruction (RD-HIR), and double-low-dose data were reconstructed using both HIR (LD-HIR) and DLR (LD-DLR). The consistency of both coronary stenosis assessments and CT-derived fractional flow reserve (CT-FFR) values between low-dose and routine-dose images was quantified using receiver operating characteristic analysis at various levels. Segment-level image quality scores (IQS), signal-noise-ratio (SNR), and contrast-noise-ratio (CNR) were compared among three groups. Results Double-low-dose CCTA achieved a significant reduction in both radiation dose (0.60 ± 0.12 mSv vs 4.43 ± 1.42 mSv) and contrast volume compared to routine-dose CCTA. For the per-segment level, LD-DLR showed significantly higher specificity (0.99 vs 0.94), positive predictive value (0.91 vs 0.68), and accuracy (0.98 vs 0.94) for ≥ 50% coronary stenosis compared to LD-HIR. The area under the curve of LD-DLR was significantly higher than LD-HIR for ≥ 50% stenosis at per-segment (0.94 vs 0.92), per-vessel (0.92 vs 0.89), and per-patient (0.92 vs 0.85) levels; and for CT-FFR ≤ 0.80 at per-vessel (0.94 vs 0.74), LAD-vessel (0.94 vs 0.71), and LCX-vessel (0.99 vs 0.67) levels. The IQS, SNR, and CNR of LD-DLR were not inferior to those of RD-HIR in all segments. Conclusions The 60 kVp double-low-dose CCTA with DLR can significantly reduce radiation dose and simultaneously maintain the high consistency of coronary stenosis and CT-FFR assessments with routine-dose CCTA. Critical relevance statement The 60 kVp double-low-dose CCTA protocol is feasible with a novel DLR algorithm without compromising the performance of coronary stenosis and CT-FFR assessments. Key Points Is a 60 kVp double-low-dose CCTA protocol with a DLR algorithm feasible for routine clinical application? The 60 kVp CCTA protocol with the DLR algorithm reduced radiation dose by 86.5% and contrast dose by 36.4%. The 60 kVp CCTA with DLR achieved high consistency of coronary stenosis and CT-FFR values with the routine-dose 100 kVp CCTA.
No takes yet. Share an insight, caveat, or question.
Wu et al. (2026) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: