Systematic review reveals how implant design influences outcomes and complications in total ankle arthroplasty, suggesting design evolution is key.
Background Total ankle arthroplasty (TAA) is increasingly used as an alternative to arthrodesis for end-stage ankle arthritis. The extent to which implant bearing type and design evolution influence outcomes and survival remains debated. Methods A systematic review and meta-analysis was conducted in accordance with PRISMA guidelines and registered on PROSPERO (CRD420251073944). PubMed, Embase, and Scopus were searched for English-language studies (2004-2025) reporting anterior-approach TAA with specified implant generation (I–IV) and bearing type (fixed [FB] vs mobile [MB]). Studies with a QualSyst score ≥ 75% were included. Primary outcomes were American Orthopaedic Foot & Ankle Society (AOFAS) score, visual analogue scale (VAS), range of motion (ROM), complications, and revisions. Results Forty-two studies comprising 4,271 implants were analyzed (FB: 1,546; MB: 2,725). Functional improvements were mainly driven by implant generation rather than bearing type. ΔAOFAS increased from 33.7 ± 22.3 in Gen II to 44.5 ± 28.3 in Gen IV (P < .001). ΔVAS varied across generations (Gen II 5.8 ± 2.1; Gen III 4.6 ± 2.8; Gen IV 5.46 ± 1.60; all P < .001 vs baseline). MB implants showed lower pre- and postoperative AOFAS scores but comparable ΔAOFAS to FB designs (36.4 vs 37.5; P = .358). MB systems provided greater pain relief (ΔVAS 5.62 vs 4.60; P < .001) but had higher revision rates (12.0% vs 6.2%; P < .001). FB implants achieved superior postoperative ROM gains in plantarflexion (+6.0° vs −2.9°; P < .001) and dorsiflexion (+2.71° vs +0.75°; P < .001). Excluding Gen I, complication rates decreased from 32.6% in Gen II to 18.8% in Gen III and 10.3% in Gen IV (all P < .01); revision rates declined from 16.5% (Gen II) and 9.6% (Gen III) to 0.5% (Gen IV) (P < .01). Conclusions Implant generation is the primary determinant of outcomes, complications, and survival in anterior-approach TAA. Bearing type played a secondary role: MB devices provided greater pain relief, whereas FB systems achieved superior ROM recovery and lower revision risk. Fourth-generation implants yielded the most reliable results. Further prospective studies with standardized functional and kinematic assessments are warranted. Level of Clinical Evidence: Level I—Systematic Review/Meta-Analysis
No takes yet. Share an insight, caveat, or question.
Gardini et al. (2026) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: