Key result
Mailed at-home HbA1c screening achieves a ~38% return rate and detects diabetes in 1.7%.
Why the study?
Is screening for type 2 diabetes using at-home self-sampling HbA1c tests feasible and cost-effective in individuals aged 50-75 without recent HbA1c measurement?
Cross-Sectional (n=8,000)
Is screening for type 2 diabetes using at-home self-sampling HbA1c tests feasible and cost-effective in individuals aged 50-75 without recent HbA1c measurement?
At-home self-sampling HbA1c tests are a feasible and potentially cost-effective strategy for targeted type 2 diabetes screening in individuals without recent testing.
Objective The increased use of HbA1c as a diagnostic criterion, novel methods to collect and store blood samples as well as the quality of national registers enable screening targeted individuals, who are not screened opportunistically. The study evaluates whether screening for type 2 diabetes using at-home self-sampling HbA1c tests, targeted people who have not had their HbA1c measured the last 2 years, is feasible and cost-effective. Research design and methods During a period of 9 months, the Danish Diabetes Association mailed free capillary at-home self-sampling HbA1c tests to 8,000 randomly selected individuals aged 50–75 years who had not had their HbA1c measured in the past 2 years. The screening costs per screen-detected derived from the pilot study and estimated cost savings across HbA1c levels derived from a Danish simulation study was used to estimate cost-effectiveness. Results About 38% returned a blood sample. The share of participants with HbA1c of 48 mmol/mol (6.5%) and above was 1.7% (50/2913). The screening costs were 1.207 per screen-detected with type 2 diabetes. A national screening program targeting individuals aged 50 to 75 years, who have not had their HbA1c measured within the previous 2 years, is estimated to reduce healthcare costs and productivity losses by €1514 per screen-detected, if diagnosis is moved forward by 3 years, as derived from a Danish simulation study. Hence, the total social return ratio of the screening program is estimated to €1514/ €1183=1.28. Conclusions The study suggests that screening for type 2 diabetes using at-home self-sampling HbA1c tests, targeting individuals aged 50–75, who have not had their HbA1c measured the past 2 years, is feasible and cost-effective in Denmark.
No takes yet. Share an insight, caveat, or question.
Mateu et al. (2026) conducted a cross-sectional in Type 2 diabetes (n=8,000). At-home self-sampling HbA1c tests was evaluated on Return rate of blood sample and detection of HbA1c ≥48 mmol/mol (6.5%). At-home self-sampling HbA1c screening yielded a 38% return rate, detecting type 2 diabetes in 1.7% of participants, with an estimated total social return ratio of 1.28.