Key result
Insulin pumps do not alter overall HbA1c or disordered eating, though closed-loop systems lower HbA1c.
Why the study?
Many adolescents with type 1 diabetes, particularly those with disordered eating behaviors, struggle to reach glycemic targets and have higher HbA1c levels despite improvements in diabetes management.
Does insulin pump implementation improve HbA1c and disordered eating behaviors in adolescents with type 1 diabetes?
Cohort (n=38)
Does insulin pump implementation improve HbA1c and disordered eating behaviors in adolescents with type 1 diabetes?
Insulin pump implementation did not significantly improve overall HbA1c or disordered eating behaviors in adolescents with T1D, though hybrid closed-loop systems were associated with reduced HbA1c.
No support for routine pump initiation to target HbA1c or disordered eating in T1D adolescents; leaves open hybrid closed-loop benefits.
Aims: Despite improvement in diabetes management, many adolescents with type 1 diabetes (T1D), especially those with disordered eating behaviors (DEB), struggle to reach glycemic targets and have higher HbA1c levels. We aimed to evaluate HbA1c and DEB trends in adolescents with T1D following insulin pump implementation. Methods: This prospective longitudinal study, with 12 months follow-up, included adolescents (n=38) with T1D aged 10-20 years, who were assessed at baseline (prior to insulin pump implementation), and at 2-, 6-, and 12-months post-implementation. Data were collected from medical charts and self-reported questionnaires. Results: HbA1c and DEB levels showed no significant changes over time. However, adolescents with DEB consistently had higher HbA1c levels than those without (P = 0.003). Both HbA1c and DEB were elevated in adolescents with body dissatisfaction, particularly those desiring thinner bodies (P = 0.012 and P < 0.001, respectively). HbA1c trends varied by insulin delivery method (P = 0.005), with the greatest reduction observed in users of hybrid closed-loop (HCL) systems (P = 0.04). Conclusions: Despite insulin pump implementation, no significant overall changes were observed in HbA1c or DEB levels across the study period. However, adolescents using HCL systems showed reduced HbA1c, while levels remained elevated among those with DEB. Both HbA1c and DEB were higher in adolescents with body dissatisfaction, particularly those desiring thinner bodies. These findings highlight the need for targeted support during the adoption of diabetes technologies. Larger studies are warranted to guide effective interventions for this high-risk population.
No takes yet. Share an insight, caveat, or question.
Propper-Lewinsohn et al. (2026) conducted a cohort in Type 1 diabetes (n=38). Insulin pump implementation vs. Baseline (prior to implementation) was evaluated on HbA1c and disordered eating behaviors (DEB) trends. Insulin pump implementation did not significantly change overall HbA1c or disordered eating behavior levels over 12 months, though hybrid closed-loop system users showed reduced HbA1c (P=0.04).
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: