Answers are grounded in this paper and cite their sources.
Cohort analysis identifies adverse events including gastro-enterocolic fistula after EUS-guided gastroenterostomy, suggesting challenges in management.
Background: EUS-guided gastroenterostomy (EUS-GE) is an effective option for the management of gastric outlet obstruction (GOO). Due to the poor prognosis of patients undergoing it, data on its long-term adverse events (AE) is scarce. Herein, we describe a cohort of patients with gastro-entero-colic fistula (GECF) as a late AE of previously successful EUS-GE. Methods: Patients who developed a GECF after EUS-GE from 10 high-volume centers were analyzed. Information collected included demographic characteristics, indications, clinical and technical success rates, stent type and size, fistula characteristics, management, and outcomes. Results: Sixteen cases were identified. The mean interval from index EUS-GE to the diagnosis of GECF was 4 to 8 weeks. The most common cause of GOO was pancreatic adenocarcinoma (PDAC). The transverse colon was the most common site for the GECF (14 patients). A 20×10 mm lumen apposing metal stent (LAMS) was utilized in 10 patients. Endoscopic management with a variety of modalities was successful in 13 cases. Follow-up interval after endoscopic management of the fistula averaged 2 to 4 weeks. At the time of the manuscript elaboration, 10 patients had died, 5 were alive, and 1 was lost to follow-up. Conclusions: This is the first description of a cohort of patients with GECF after EUS-GE. The exact mechanisms leading to GECF in these cases are unknown. Possible explanations include inadvertent colon puncture during the index procedure and/or entrapment of mesocolon. More data is needed to further characterize this AE.
No takes yet. Share an insight, caveat, or question.
Ladd et al. (2025) studied this question.
Synapse has enriched 8 closely related papers on similar clinical questions. Consider them for comparative context: