Background: EUS-guided gastroenterostomy (EUS-GE) is an effective option for the management of gastric outlet obstruction (GOO). Due to the poor prognosis of patients undergoing it, data on its long-term adverse events (AE) is scarce. Herein, we describe a cohort of patients with gastro-entero-colic fistula (GECF) as a late AE of previously successful EUS-GE. Methods: Patients who developed a GECF after EUS-GE from 10 high-volume centers were analyzed. Information collected included demographic characteristics, indications, clinical and technical success rates, stent type and size, fistula characteristics, management, and outcomes. Results: Sixteen cases were identified. The mean interval from index EUS-GE to the diagnosis of GECF was 4 to 8 weeks. The most common cause of GOO was pancreatic adenocarcinoma (PDAC). The transverse colon was the most common site for the GECF (14 patients). A 20×10 mm lumen apposing metal stent (LAMS) was utilized in 10 patients. Endoscopic management with a variety of modalities was successful in 13 cases. Follow-up interval after endoscopic management of the fistula averaged 2 to 4 weeks. At the time of the manuscript elaboration, 10 patients had died, 5 were alive, and 1 was lost to follow-up. Conclusions: This is the first description of a cohort of patients with GECF after EUS-GE. The exact mechanisms leading to GECF in these cases are unknown. Possible explanations include inadvertent colon puncture during the index procedure and/or entrapment of mesocolon. More data is needed to further characterize this AE.
Ladd et al. (Wed,) studied this question.