Answers are grounded in this paper and cite their sources.
A novel method detects leakage in branch pipelines, suggesting improved accuracy through information fusion.
To solve the problem of a high false positive rate in leakage detection in branch pipelines, this paper proposes a pipeline detection method based on acousto-pressure signal information fusion. The transformer architecture is introduced as the basic mode of the acousto-pressure fusion diagnosis model to enhance the signal timing feature extraction ability. The cross-self-attention mechanism is used to make the sound signal and pressure signal interact and fuse in the process of feature extraction, so as to realise end-to-end branch pipeline fault diagnosis. Firstly, the noise reduction method of complementary ensemble empirical mode decomposition-least mean squares (CEEMD-LMS) is used to denoise the collected sound pressure signal. Secondly, an acousto-pressure cross-fusion model based on a cross-fusion transformer is proposed to fuse the information in two types of denoised signal and classify different leakage types. The experimental results show that the accuracy of leakage detection for a 2 mm leak size is 97.21%, while the accuracies of leakage detection for 5 mm and 8 mm sizes are 98.57% and 98.94%, respectively. The accuracy of the model for detecting the presence or absence of any leakage is 99.03%, which verifies the effectiveness of the proposed method.
No takes yet. Share an insight, caveat, or question.
Yang et al. (2026) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: