Answers are grounded in this paper and cite their sources.
Simulation methodology models dual fuel combustion in internal combustion engines, highlighting flame sensitivity.
This article presents the simulation methodology and results of dual fuel combustion for internal combustion engines (ICE). Simulations were performed in ANSYS Forte®, which modeled flame propagation using the G-equation model, and results were validated against experimental data. The article also presents results from simulations performed in Converge CFD®, which used the SAGE combustion model, presented in previous work. Typical combustion modelling challenges in such ICE simulations are discussed, and the applied methodology is described. The range of methane-air equivalence ratio was 0.47 ≤ ϕ ≤0.57 across four load conditions with a rotational velocity range of 1228 ≤ RPM ≤ 1800. The methane-air combustion at these low equivalence ratios led to the required tuning of the stretch factor coefficient used in the flame speed model in ANSYS Forte® due to methane’s thermo-diffusive effects at lean equivalence ratios. As a result, the flame stretch factor coefficient was found to increase with decreasing equivalence ratio. The study thus demonstrates the importance of flame stretch sensitivity and thermo-diffusive instabilities in ICE combustion through CFD combustion simulations.