Answers are grounded in this paper and cite their sources.
Reports a dual-mode approach for detecting E. coli in water, highlighting rapid monitoring implications.
Rapid and reliable detection of Escherichia coli ( E. coli ) in water is critical for safeguarding public health. We developed a dual‐mode biosensor that integrates p‐benzoquinone (BQ)‐mediated colorimetric prescreening with antibody‐based electrochemical quantification using screen‐printed gold electrodes (SPGEs). BQ serves a dual role by generating a visible color change through its enzymatic reduction by viable E. coli and by participating in a reversible redox cycle that enhances faradaic response during electrochemical analysis. The biosensing platform was validated using E. coli ATCC 25922 together with broad‐serotype polyclonal anti‐ E. coli O/K antibodies, which enable species‐level recognition. Under optimized conditions (6.0 mM BQ, 25 µg/mL antibody), the sensor achieved a wide linear range from 10 1 to 10 9 CFU/mL with a detection limit of 0.57 CFU/mL. Repeatability was excellent (1.51% RSD), and specificity tests demonstrated clear discrimination between viable E. coli , nontarget bacteria ( S. aureus ), and nonviable cells. This dual‐selectivity strategy, combining metabolic activity with molecular recognition, offers a rapid and portable approach for on‐site microbial water quality monitoring.
No takes yet. Share an insight, caveat, or question.
Ucar et al. (2026) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: