February 21, 2026Analele Universităţii Dunărea de Jos din Galaţi Fascicula XI Construcţii navale/ Annals of Dunărea de Jos of Galati Fascicle XI Shipbuilding0 citationsOpen Access

Local structural analysys of potable water system foundation

ADAlina DescaluiCUCostel UngureanuCGCarmen Marilena GASPAROTTI

Key Points

  • Evaluate the structural behavior of a steel foundation under various loads and propose improvements.
  • Local structural analysis using finite element method in ANSYS Mechanical
  • 3D CAD modeling of foundation structure
  • Evaluation of three foundation variants: initial design, stiffened version, and closed-section frame
  • Analysis of deformations and von Mises stresses against serviceability criteria
  • Optimized foundation significantly reduces maximum deformations
  • Improves dynamic behavior without exceeding steel stress limits
  • Stiffened foundation performed better compared to the initial design

Abstract

This paper presents the local structural analysis of a steel foundation supporting the pumps of a potable water system installed on a 30,000 DWT Handymax bulk carrier. The aim is to evaluate the structural behaviour of the foundation under static and dynamic loads representative for shipboard service and to propose simple constructive improvements that enhance stiffness and vibration performance. The potable water system is briefly described, including design requirements, sizing of the pumps, hydrophore unit and heat exchanger. The support structure is modelled in 3D CAD and analysed using the finite element method in ANSYS Mechanical, considering the mass of the pump unit and excitation frequencies up to 60 Hz. Three foundation variants are investigated: the initial design, a stiffened version obtained by adding local reinforcements and an alternative closed-section frame using rectangular hollow profiles. For each model, deformations and equivalent von Mises stresses are evaluated and compared with the yield limit of steel S235JR and with serviceability criteria from Eurocode 3. The results show that the optimized foundation with rectangular hollow sections significantly reduces maximum deformations and improves dynamic behaviour, without exceeding allowable stress levels. Recommendations for monitoring, maintenance and vibration isolation using spring-type anti-vibration mounts are also formulated.