PulseExploreJournal ClubDebatesTrendingResearchersJournals
Instagram
HomeExploreJournal ClubTrending
Synapse
⌘+K
Synapse
February 21, 2026Pharmaceutical Research1 citationsOpen Access

The Advanced Integrated Respiratory (AIR) Model: Comparative Analysis of Salbutamol Sulphate Deposition from pMDI, DPI, and Nebuliser Versus the NGI

PHPatrick HeWoolcock Institute of Medical ResearchHLHazel LamWoolcock Institute of Medical ResearchDCDamien ChongDefence Science and Technology Group

Key Points

  • This research aims to compare the deposition of salbutamol sulphate using the AIR model and the NGI.
  • Utilized the Advanced Integrated Respiratory (AIR) model for aerosol delivery assessment.
  • Delivered salbutamol sulphate via pMDI, DPI, and jet nebuliser.
  • Compared deposition profiles of each platform against results from the Next Generation Impactor (NGI).
  • DPI and nebuliser aerosols showed consistent deposition patterns in the AIR and NGI models.
  • pMDI testing revealed higher oropharyngeal retention and lower intrathoracic delivery compared to the NGI.
  • Findings from the AIR model align more closely with in vivo scintigraphy studies regarding pMDI delivery.

Abstract

Abstract Purpose In vitro respiratory models such as the Next Generation Impactor (NGI), remain the gold standard for aerodynamic particle size distribution (APSD) testing, however, they lack the anatomical complexity, limiting their ability to replicate in vivo deposition. To address this limitation, the Advanced Integrated Respiratory (AIR) model, a physiologically relevant benchtop system incorporating anatomically accurate silicone casts of the upper and lower airways, was used to assess deposition of salbutamol sulphate delivered via three clinically relevant platforms. Methods Salbutamol sulphate was delivered using a pressurised metered-dose inhaler (pMDI), a dry powder inhaler (DPI), and a jet nebuliser. Deposition profiles obtained in the AIR model were benchmarked against the NGI. Results Both systems showed consistent patterns for DPI and nebuliser aerosols, with highest deposition in the oropharyngeal and intrathoracic regions, respectively. In contrast, pMDI testing revealed important differences: the AIR model predicted markedly higher oropharyngeal retention and reduced intrathoracic delivery, aligning more closely with published in vivo scintigraphy studies than the NGI. Conclusion These findings demonstrate that anatomically realistic models provide critical insights into deposition behaviour, particularly for propellant driven inhalers and underscore the value of integrating physiologically relevant platforms alongside conventional impactors in aerosol characterisation.