February 22, 2026Biomedical Engineering / Biomedizinische Technik0 citationsOpen Access

Blood pressure estimation using single photoplethysmography signal based on ResNet-BiGRU

GFGongwei FanYPYuhao PangWZWei Zheng

Key Points

  • This research aims to create a deep learning framework for accurate cuffless blood pressure estimation using a single photoplethysmography signal.
  • Developed a hybrid deep neural network called ResNet-BiGRU combining residual convolutional blocks and bidirectional gated recurrent units.
  • Used the UCI Cuff-Less Blood Pressure Estimation Dataset for model training and validation.
  • Applied a bandpass filter and segmented data into 5-second windows for analysis.
  • Conducted external evaluation using the VitalDB dataset from surgical patients.
  • Achieved mean absolute errors of 4.78 mmHg for systolic BP and 2.98 mmHg for diastolic BP on the UCI dataset.
  • Achieved mean absolute errors of 8.15 mmHg for systolic BP and 4.59 mmHg for diastolic BP on the VitalDB dataset.

Abstract

Abstract Objectives Conventional cuff-based blood pressure (BP) measurement provides only intermittent readings, whereas photoplethysmography (PPG)-based methods enable continuous and noninvasive monitoring. This study aims to develop a deep learning framework for accurate, cuffless BP estimation using a single PPG signal. Methods A hybrid deep neural network, termed ResNet-BiGRU, was developed by integrating residual convolutional blocks with bidirectional gated recurrent units to jointly capture morphological and temporal features. The UCI Cuff-Less Blood Pressure Estimation Dataset (a subset of MIMIC-II), which contains synchronized PPG and arterial blood pressure (ABP) signals from 942 subjects, was used for model training and validation. After applying a 0.5–8 Hz bandpass filter and segmenting into 5 s windows, the data were split 80/20 for training and validation. External evaluation was conducted using the VitalDB dataset, which provides synchronized PPG and ABP recordings from surgical patients under diverse physiological conditions. Results The model achieved mean absolute errors (MAE) of 4.78 mmHg for systolic BP (SBP) and 2.98 mmHg for diastolic BP (DBP) on UCI, and 8.15 mmHg for SBP and 4.59 mmHg for DBP on VitalDB. Conclusions The ResNet-BiGRU model demonstrates accurate, robust, and generalizable cuffless BP estimation, showing strong potential for wearable health monitoring applications.