Answers are grounded in this paper and cite their sources.
Ex vivo study compares gap formation in iliopsoas tendon reinsertion using bone tunnel versus bioabsorbable anchor, highlighting effectiveness.
This study aimed to compare gap formation between a classical transcalcaneal bone tunnel and a bioabsorbable suture anchor in a feline Achilles tendon avulsion model. Gastrocnemius tendons were dissected from the calcaneus of seven pairs of feline gastrocnemius tendon–calcaneus specimens. Reinsertion was performed either through a transverse bone tunnel or with a bioabsorbable suture anchor with a metric 3 non-absorbable monofilament polypropylene–polyethylene suture in a Bunnell–Mayer pattern. Tensile tests were conducted under physiological loading conditions. Gap formation was tracked with a video camera, and force on the tendon was measured. Results were compared with t-tests. Mean load at a gap of 0.5 mm was significantly higher for the suture anchor (44.2 ± 5.5 N) compared with the bone tunnel (23.0 ± 15.4 N). A 3-mm gap was not reached with the suture anchor. Failure loads were dominated by suture breakage and were not significantly different between suture anchor (55.2 ± 8.0 N) and bone tunnel (65.1 ± 8.3 N). Pulling through the tendon substance did not occur. The suture anchor resisted gap formation more effectively than the bone tunnel and can be considered advantageous for gastrocnemius tendon reinsertion in cats.
No takes yet. Share an insight, caveat, or question.
Groß et al. (2026) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: