February 27, 2026Applied Thermal Engineering5 citationsOpen Access

Enhanced direct-contact condensation and entrainment in a three-nozzle eductor for thermal vacuum desalination: experimental and CFD study

View Full Paper
RDRatan Kumar DasOTOranit TraisakWLWai Hong Lai

Key Points

  • The study aims to investigate the performance of three-nozzle eductors for improved vapor entrainment and condensation in thermal vacuum desalination.
  • Conducted experimental tests on single- and three-nozzle eductors.
  • Utilized ANSYS Fluent simulations to model two-phase steam-water operation.
  • Varied inter-nozzle spacing and nozzle splitting ratios to evaluate effects on performance.
  • Achieved 107–163% increase in entrainment ratio with optimized nozzle spacing.
  • Validated CFD results showed RMSE of 2–3% against experimental data.
  • Enhanced entrainment capacity reached 24 kg/h with reduced specific energy consumption by ~2 kWh/m³.

Abstract

Eductors offer a compact and low-maintenance alternative to conventional thermally driven vacuum systems in desalination, which typically rely on energy-intensive condensers and pumps. By employing direct-contact condensation (DCC), eductors can simultaneously generate a vacuum and entrain vapor, enabling simpler and more energy-efficient desalination modules. However, optimization of multi-nozzle geometries for two-phase flows remains limited. This study presents a combined experimental and numerical investigation of single- and three-nozzle eductors, focusing on the effects of inter-nozzle spacing ratio (D n /D) and nozzle splitting ratio (R s ) under two-phase steam–water operation. Three-dimensional ANSYS Fluent simulations were validated against experimental pressure and temperature data at five axial stations, showing RMSE within 2–3%. Results indicate that inter-nozzle spacing significantly affects entrainment and condensation. At D n /D = 0.29, the three-nozzle eductor achieved optimum performance, improving the entrainment ratio by 107–163% compared with the single-nozzle design. Flow visualizations confirmed enhanced vapor entrainment and intensified condensation within inter-nozzle gaps. Lower suction vapor temperature deepened the vacuum and extended the condensation region, while higher back pressure suppressed entrainment. The optimized three-nozzle eductor entrained up to 24 kg/h of vapor, corresponding to ~24 kg·m −2 ·h −1 VMD flux for a 1 m 2 membrane, with specific energy consumption reduced by ~2 kWh·m −3 relative to the single nozzle. These findings establish condensation-driven entrainment, rather than vacuum generation alone, as the dominant vapor entrainment mechanism and demonstrate that optimized multi-nozzle eductors can substantially enhance the performance and compactness of thermal vacuum desalination systems. • Combined experimental and CFD study of a two-phase three-nozzle eductor. • Optimum spacing and split increased entrainment by 107–163%. • Interacting jets intensified vapor–liquid mixing and condensation. • Condensation-driven entrainment sustained stronger vacuum generation. • Achieved ~24 kg m −2 h −1 flux with lower energy use than single nozzle.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Das et al. (2026) studied this question.

synapsesocial.com/papers/69a134b8ed1d949a99abe3dbhttps://doi.org/10.1016/j.applthermaleng.2026.130418
Ask AI
Helpful
Bookmark
Share
View Full Paper

Also Consider

Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context:

  1. 1Parametric study of low‐temperature solar‐assisted flash evaporation desalination systems using two‐phase water–steam ejector2024
  2. 2Numerical Investigation on the Heat and Mass Transfer Characteristics of Direct Contact Condensation in a Water-Driven Steam Ejector2026
  3. 3Numerical Investigation of a Two-Phase Ejector Operation Taking into Account Steam Condensation with the Presence of CO22024 · 5 citations
  4. 4CFD-Based Optimization of the Supersonic Nozzle Used in Ejector Refrigeration Systems2025
  5. 5Thermal Performance Evaluation of Flash Evaporation in Wickless Heat Pipes With Jet Nozzle for Desalination2025