Development, validation, and biomechanical evaluation of a high-fidelity finite element model of the forearm musculoskeletal system

RSRu-Guo ShangSXSiyuan XieLLLi-qing Liao

Key Points

  • The aim is to develop and validate a high-fidelity finite element model of the forearm to replicate stress distribution under loading conditions.
  • Constructed 3D finite element model using CT and MRI data from a cadaveric specimen
  • Segmented geometries of bones, muscles, ligaments, tendons, and cartilage using specialized software
  • Assigned material properties based on literature and performed mesh convergence testing
  • Conducted axial compression tests to validate the model against cadaveric measurements
  • The model accurately predicted peak contact stresses of 4.8 MPa (radioscaphoid) and 2.75 MPa (radiolunate)
  • Contact area was consistent, measuring 22.5% compared to experimental data
  • Stress differences during mesh convergence were less than 5%
  • The model's muscle belly length matched cadaveric measurements

Abstract

The human forearm, a dynamically coordinated system of bones, muscles, and connective tissues, is central to upper limb function but poses significant challenges for computational modeling due to its anatomical complexity. Existing finite element (FE) models of the forearm often oversimplify soft tissues or lack rigorous validation, limiting their clinical utility. This study aimed to develop and validate a high-fidelity 3D FE model of the forearm musculoskeletal system to replicate in vivo stress distribution under axial loading. The model was constructed using CT and MRI data from a fresh-frozen cadaveric specimen (MorphoSource) and validated with embalmed specimen, combined with anatomical references. Bone, muscle, ligaments, tendons, and cartilage geometries were segmented and optimized using Mimics 19.0, Geomagic Wrap 2017, and SolidWorks 2021. Material properties (isotropic, linear elastic) were assigned based on literature, and mesh convergence was validated. Mechanical validation included mesh convergence testing, geometric comparison with cadaveric measurements and literature data, and axial compression tests (100 N) to simulate physiological loading. A 3D FE model with 672,411 elements and 1,080,964 nodes was successfully built, reconstructing bones, muscles, tendons, ligaments, and cartilage. Mesh convergence testing showed stress differences < 5%. FE model’s muscle belly length matched cadaveric measurements and literature values. Under 100 N axial load, the model predicted peak contact stresses of 4.8 MPa (radioscaphoid) and 2.75 MPa (radiolunate), with a 22.5% contact area, consistent with cadaveric experiments (5.13 MPa, 23.11%) and prior literature (5.24 MPa, 20.1–20.6%). This high-fidelity FE model accurately replicates forearm anatomy and in vivo stress distribution, validated against cadaveric and literature data. It provides a robust platform for exploring forearm biomechanics and guiding clinical applications (e.g., surgical planning, implant design). Limitations include dynamic material properties and single-specimen validation, which warrant future studies with dynamic parameters and multi-specimen data. This framework advances translational biomechanics by bridging computational precision with anatomical realism.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Shang et al. (2026) studied this question.

synapsesocial.com/papers/69a2877b0a974eb0d3c03399https://doi.org/10.1186/s12891-026-09672-6
Ask AI
Helpful
Bookmark
Share
View Full Paper

Also Consider

Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context:

  1. 1Biomechanical investigation of a novel hybrid dorsal double plating for distal radius fractures by integrating topology optimization and finite element analysis2020 · 23 citations
  2. 2Pressure distribution in the wrist joint1988 · 70 citations
  3. 3Sarcopenia: revised European consensus on definition and diagnosis2018 · 14,321 citations
  4. 4Role of the extensor carpi ulnaris and its sheath on dynamic carpal stability2011 · 50 citations
  5. 5The Forearm Complex: Anatomy, Biomechanics and Clinical Considerations2006 · 60 citations