Key result
Adaptive denoising algorithm improves output SNR to ~15 dB in simulations and vascular phantoms.
Why the study?
Laser Doppler flow signal processing is limited by composite noise, non-stationarity, and the inability of traditional threshold methods to balance noise suppression with signal fidelity.
An adaptive denoising algorithm integrating temporal noise perception and DWT effectively suppresses composite noise in laser Doppler flow signals, outperforming traditional methods.
May improve reliability of laser Doppler flowmetry in clinical vascular evaluation; extends prior signal processing techniques for cardiovascular researchers.
Addressing the challenges of composite noise (speckle noise, thermal noise, and random pulse interference) and non-stationarity in laser Doppler flow (LDF) signal processing, as well as the technical limitation of traditional threshold methods in balancing noise suppression and signal fidelity, this study proposes an adaptive denoising algorithm integrating temporal noise perception and discrete wavelet transform (DWT). A composite noise model is first established to characterize the interference. The signal undergoes a five-level DWT decomposition, where a local energy detection mechanism distinguishes signal-dominant from noise-dominant regions. An SNR-driven dynamic thresholding strategy is generated by combining inter-layer adaptive allocation with coefficient-level local weighting, followed by processing with an improved smoothing function to effectively suppress reconstruction artifacts. Simulations at a 1 dB input signal-to-noise ratio (SNR) yielded a 15.45 dB output SNR and a 0.05634 root mean square error (RMSE), outperforming traditional wavelet methods and modern benchmarks such as local variance and variational mode decomposition (VMD). Applied to a practical signal from an isolated vascular phantom with an initial SNR of −1.04 dB, the algorithm achieved a 13.86 dB output SNR and a 0.00258 RMSE. Results confirm the algorithm’s effectiveness for high-fidelity waveform capture in complex noise environments, offering a robust solution for vascular hemodynamic monitoring
No takes yet. Share an insight, caveat, or question.
Sun et al. (2026) studied this question. The proposed adaptive denoising algorithm improved output SNR to 15.45 dB from 1 dB input in simulations and to 13.86 dB from -1.04 dB in vascular phantom signals.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: