Key result
Novel smartwatch PPG algorithm successfully detects terminal cardiac arrest in a single-patient case study.
Why the study?
Does a retrospectively applied diagnostic algorithm using commercial smartwatch photoplethysmography data accurately detect terminal cardiac arrest in a palliative patient?
Case Report (n=1)
No
Does a retrospectively applied diagnostic algorithm using commercial smartwatch photoplethysmography data accurately detect terminal cardiac arrest in a palliative patient?
This case report provides the first detailed evidence demonstrating the technical feasibility of detecting a spontaneous, non-procedural cardiac arrest using photoplethysmography data from a consumer-grade smartwatch.
Feasibility of smartwatch arrest detection shown in one palliative case; leaves open prospective validation for real-time emergency use.
Background: Automated cardiac arrest detection aims to shorten the time between arrest onset and emergency medical services activation, thereby reducing the number of unwitnessed out-of-hospital cardiac arrests (OHCA) and shortening time to treatment in witnessed OHCA. Current arrest detection algorithms are largely developed using simulated or artificially induced cardiac arrest data. To our knowledge, this case report provides the first detailed description of the automated detection of spontaneous, non-procedural, end-of-life cardiac arrest using consumer-grade smartwatch-derived sensor data. Case report: An 82-year-old patient presented to the emergency department with a severe intracerebral hemorrhage with poor prognosis. Following shared decision-making with the family, palliative management was initiated. The patient was continuously monitored with electrocardiography (ECG), invasive arterial blood pressure, and clinical photoplethysmography (PPG). In addition, a commercial smartwatch was placed on the wrist to collect sensor data during the palliative phase and up to 20 min after confirmed cardiac arrest. The smartwatch PPG data were retrospectively analyzed using a previously described diagnostic algorithm. This preliminary algorithm detects circulatory arrest using the photoplethysmography sensor signals acquired from a commercial smartwatch. The algorithm accurately identified the moment of cardiac arrest in concordance with the clinical reference signals. Informed consent was obtained for this research from a legal representative. Conclusion: Although this controlled end-of-life setting does not represent the circumstances of an OHCA, this case demonstrates the feasibility of detecting true cardiac arrest using a commercial available smartwatch. Prospective studies in real-world OHCA populations are needed to assess clinical performance and practical applicability.
No takes yet. Share an insight, caveat, or question.
Beuken et al. (2026) conducted a case report in Cardiac arrest (n=1). Automated cardiac arrest detection algorithm using a commercial smartwatch (Samsung Watch5 Pro) vs. Clinical monitoring (ECG, invasive arterial blood pressure, clinical PPG) was evaluated on Detection of circulatory arrest using smartwatch photoplethysmography sensor signals. A commercially available smartwatch, analyzed retrospectively with a novel algorithm, successfully detected the moment of terminal cardiac arrest in an 82-year-old male patient.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: