Key result
Novel wearable HR model outperforms EKF methods for core temperature tracking with ~0.37°C error.
Why the study?
Accurate and continuous assessment of physiological heat strain is increasingly important as global temperatures rise and heat-exposure scenarios become more common across occupational, athletic, and built environments.
Does a physiologically informed probabilistic model using wearable heart rate sensors improve the accuracy of real-time core body temperature estimation compared to established EKF-based approaches?
Does a physiologically informed probabilistic model using wearable heart rate sensors improve the accuracy of real-time core body temperature estimation compared to established EKF-based approaches?
A novel probabilistic modeling framework can transform standard wearable heart rate sensors into accurate, real-time core body temperature monitors for heat stress monitoring.
Facilitates real-time heat stress management to lower cardiovascular risk in vulnerable populations; extends the utility of wearable HR sensors for researchers and clinicians.
Accurate and continuous assessment of physiological heat strain is increasingly important as global temperatures rise and heat-exposure scenarios become more common across occupational, athletic, and built environments. This study proposes a novel framework that enables a standard wearable heart-rate (HR) sensor to function as a real-time CBT estimation system. The method integrates a probabilistic Hidden Markov Model that captures the shifting physiological states of exercise and recovery with a non-parametric Particle Filter that models nonlinear thermophysiological dynamics. A bidirectional coupling between these components allows state-conditioned likelihoods from the filter to refine the HMM belief, while the updated state probabilities guide subsequent filter updates through soft switching. An improved genetic algorithm further enhances robustness during resampling. Across two independently collected exercise–heat-stress datasets, the proposed model achieved the best accuracy (RMSE = 0.359 C and 0.371 C), outperforming established EKF-based approaches. These findings demonstrate that physiologically informed, probabilistic modeling can transform ubiquitous wearable devices into practical tools for real-time heat-strain monitoring in hot environments. • Transforms common wearable HR sensors into real-time core temperature monitors. • A physiologically aware algorithm interprets HR dynamics to estimate core temperature. • Enables continuous thermal strain monitoring on wearables for physical activities.
No takes yet. Share an insight, caveat, or question.
Zhao et al. (2026) studied this question. A novel model using wearable heart rate sensors estimated core body temperature with RMSE of 0.36-0.37°C, outperforming EKF methods for heat stress monitoring.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: