Key result
Integrated 3D EAM with PFA associates with lower time, radiation, and costs vs conventional mapping.
Why the study?
Does an integrated 3D electroanatomic mapping platform improve procedural characteristics and reduce costs compared to conventional mapping systems in patients undergoing pentaspline pulsed field ablation for atrial fibrillation?
Observational (n=448)
Yes
Does an integrated 3D electroanatomic mapping platform improve procedural characteristics and reduce costs compared to conventional mapping systems in patients undergoing pentaspline pulsed field ablation for atrial fibrillation?
Integrated 3D electroanatomic mapping during pentaspline pulsed field ablation for AF significantly reduces procedure time, radiation exposure, and material costs compared to conventional mapping.
Answers are grounded in this paper and cite their sources.
Supports consideration of integrated 3D EAM with pentaspline PFA for AF; extends consensus to pulsed field technology.
INTRODUCTION: Pulsed field ablation (PFA) is an established therapy for atrial fibrillation (AF), yet optimal mapping strategies during pentaspline PFA remain uncertain. We compared procedural characteristics and material costs of an integrated 3D electroanatomic mapping (EAM) platform with conventional mapping systems. METHODS AND RESULTS: In a multicenter observational study of 448 consecutive AF ablations done using pentaspline catheter (62 integrated mapping; 386 conventional mapping) performed between February 2024 and August 2025, baseline characteristics were similar between groups. Compared with conventional mapping, the integrated platform was associated with shorter total procedure time (49 ± 16 vs. 66 ± 26 min, p < 0.001), shorter left atrial dwell time (35 ± 12 vs. 46 ± 30 min, p < 0.001), reduced fluoroscopy time (6 ± 4 vs. 12 ± 7 min, p < 0.001), lower radiation dose (36 ± 10 vs. 93 ± 18 mGy, p < 0.001), and lower mean material cost ($12 958 ± 164 vs. $14 739 ± 1192, p < 0.001). Differences were consistent across lesion sets. Acute pulmonary vein isolation was achieved in all patients, with two major complications occurring in the conventional mapping group. CONCLUSION: Integrated 3D EAM during pentaspline PFA was associated with shorter procedures, lower radiation exposure, and reduced material costs. These findings support the procedural and operational advantages of integrated mapping platforms in contemporary AF ablation practice.
No takes yet. Share an insight, caveat, or question.
Badin et al. (2026) conducted an observational in atrial fibrillation (n=448). integrated 3D electroanatomic mapping (EAM) platform vs. conventional mapping systems was evaluated on total procedure time (p=<0.001). Integrated 3D electroanatomic mapping during pentaspline pulsed field ablation was associated with shorter total procedure time compared with conventional mapping.
Synapse has enriched 10 related papers. Consider them for comparative context: