A case report demonstrates successful lumen remodeling and flow reduction in an arteriovenous fistula, suggesting a novel salvage method.
Aneurysmal dilation represents a complex complication of arteriovenous fistulas (AVF) with significant clinical implications including high-output heart failure and functional impairment. We report a 46-year-old male with end-stage renal disease who developed maximum diameter 40 mm aneurysmal dilation of the cephalic vein 42 months after brachiocephalic fistula creation, with flow volume reaching 2,680 mL/min. We employed an innovative flow-targeted lumen remodeling technique combined with aneurysmectomy, utilizing computational fluid dynamics modeling to achieve optimal hemodynamic control. Using a 20Fr silicone catheter as an intraluminal template, the venous diameter was precisely reduced from 35 mm to 7 ± 1.0 mm, successfully decreasing flow volume to 850 mL/min. The patient resumed dialysis within 24 h postoperatively without requiring central venous catheterization. Three-month follow-up demonstrated sustained functional patency with maintained flow volume of 880 mL/min and normal venous pressure. This technique represents a paradigm shift in complex vascular access salvage, offering superior outcomes compared to conventional methods while preserving autogenous access and avoiding prosthetic materials.
No takes yet. Share an insight, caveat, or question.
Wang et al. (2026) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: